Page 99 - katalog_gaviota
P. 99

I06_078-100_Promo 14/08/2016 10:11 Page99

Monoblock                                                                                                                                                               99

       Mod.      HP   T°32°       T°43°                                                                                                                                 Refrigeration
                     Vol. (M3)*  Vol. (M3)*
 -5° +5°
                     Calculations based on a temperature interne -0°C
AP50-PED/A
AP75-PED/A       1/2 17,7        4                                      0000        230/1N 50Hz
AP122-PED/A
                 3/4 14,1        8,2                                    0000
                                                                        0000 R404A
                 1,2 19,3        14,2

-18° -22°            Calculations based on a temperature interne -20°C        Cold groups on "overlapping"

AN120-PED/A 1,2      3,9         2,6                                    0000  - Electronic thermostatic control. - Tropicalised hermetic unit (t° surrounding +
                                                                              43°C), ventilated evaporator. - Included Block light with micro-switch for door. -
                                                                              Auto defrost, hot gas type. (AN) Cable for connection to door heater.

AN170-PED/A 1,7      4,7         3,5                                    0000

 AN201-PED/A 2       7           4,8                                    0000

* 1m3=1000 lit.

TOP Monoblock

          Mod.   HP   T°32°       T°43°
                     Vol. (M3)*  Vol. (M3)*
   -5° +5°
                     Calculations based on a temperature interne -0°C
   SP50-PED
   SP75-PED      1/2 17,7        4                                      0000
   SP122-PED                                                            0000
                 3/4 14,1        8,2                                    0000  230/1N 50Hz
  -18° -22°
                 1,2 19,3        19,2                                   0000   R404A
   SN120-PED                                                            0000
   SN170-PED         Calculations based on a temperature interne -20°C        "Ceiling" cold groups
   SN201-PED                                                                  - Electronic "digital" microprocessor of control.
                 1,2 3,9         2,6                                          - Hermetic Unit tropicalised (t° surrounding + 43°C), ventilated evaporator.
* 1m3=1000 lit.                                                               - Light box
                 1,7 4,7         3,5                                          - Cable for the connection of the micro-switch of the door.
Bi-block                                                                      - Separated Panels already connected up in unit by a 2.5-metre cable.
                                                                              - Auto defrost warm gas type.
                                                                              (SN) Cable for connection to door heater.

                 27              4,8                                    0000

          Mod.   HP   T°32°       T°43°
                     Vol. (M3)*  Vol. (M3)*
   -5° +5°
                     Calculations based on a temperature interne -0°C
    HP50-NP
    HP75-NP      1/2 8,7         5,5                                    0000  230/1N 50Hz
    HP122-NP                                                            0000
                 3/4 12,7        7,5                                    0000   R404A
  -18° -22°      1,2 23,8        14,9
                                                                        0000  Refrigerant groups "By-block"
   HN120-NP          Calculations based on a temperature interne -20°C  0000  - Electronic microprocessor of "digital" control.
   HN170-NP                                                                   - Predisposition for the connection of light brings to room temperature.
   HN201-NP      1,2 6,2         4,5                                          - Predisposition for the connection of the micro-switch for the door.
                                                                              - Separated Panels already connected up in unit by a 5 meters cable.
* 1m3=1000 lit.  1,7 7,4         5,5                                          - Hermetic Unit tropicalised (t° surrounding + 43°C), ventilated evaporator.
                                                                              - Auto defrost of type by resistance.
                                                                              - Pipes and cables provided for the connection of the unit of condensation with the unit
                                                                              of vaporizing are 5 meters.
                                                                              (HN) Cable for connection to door heater.

                 2 9,1           6,4                                    0000
   94   95   96   97   98   99   100   101   102   103   104