Page 746 - Hall et al (2015) Principles of Critical Care-McGraw-Hill
P. 746

Chapter 49Management of the Ventilated PatientGregory A. SchmidtJesse B. Hall





                   REFERENCES

                    1. Carlucci A, Richard JC, Wysocki M, et al. Noninvasive versus     12. Hussain SNA, Mofarrahi M, Sigala I, et al. Mechanical ventila-
                      onventional mechanical ventilation: an epidemiologic survey.   tion-induced diaphragm disuse in humans triggers autophage.
                      Am J Respir Crit Care Med. 2001;163:874-880.           Am J Respir Crit Care Med. 2010;182:1377-1386.
                    2. Hilbert G, Gruson D, Vargas F. Noninvasive ventilation in     13. Demoule A, Jung B, Prodanovic H, et al. Diaphragm dysfunc-
                      immunosuppressed patients with pulmonary infiltrates, fever,   tion on admission to the intensive care unit: prevalence, risk
                      and acute respiratory failure. N Engl J Med. 2001;344:481-487.  factors,  and  prognostic  impact—a prospective  study.  Am J
                    3. Drakulovic MB, Torres A, Bauer TT, et al. Supine body position   Respir Crit Care Med. 2013;188:213-219.
                      as a risk factor for nosocomial pneumonia in mechanically ven-    14. Powers SK, Wiggs MP, Sollanek KJ, et al. Ventilator-induced
                      tilated patients: a randomised trial. Lancet. 1999;354:1851-1858.  diaphragm dysfunction: cause and effect.  Am  J  Physiol  Regul
                    4. Nieuwenhoven CA, Vandenbroucke-Grauls C, van Tiel FH,   Integr Comp Physiol. 2013;305(5):R464-R477.
                      et al. Feasibility and effects of the semirecumbent position to     15. Repessé X, Charron C, Vieillard-Baron A. Right ventricular
                      prevent ventilator-associated pneumonia: a randomized study.   failure in acute lung injury and acute respiratory distress syn-
                      Crit Care Med. 2006;34:396-402.                        drome. Minerva Anestesiol. 2012;78:941-948.
                    5. Fink JB, Krause SA, Barrett L, et al. Extending ventilator cir-    16. Jubran A, Mathru M, Dries D, et al. Continuous recordings of
                      cuit change interval beyond 2 days reduces the likelihood of   mixed venous oxygen saturation during weaning from mechan-
                      ventilator-associated pneumonia. Chest. 1998;113:405-411.  ical ventilation and the ramifications thereof. Am J Respir Crit
                    6. Girard TD, Kress JP, Fuchs BD, et al. Efficacy and safety of a   Care Med. 1998;158:1763-1769.
                      paired sedation and ventilator weaning protocol for mechani-    17. Marini JJ, Capps JS, Culver BH. The inspiratory work of breathing
                      cally ventilated patients in intensive care (Awakening and   during assisted mechanical ventilation. Chest. 1985;87:612-618.
                      Breathing Controlled trial): a randomized controlled trial.     18. The Acute Respiratory Distress Syndrome Network. Ventilation
                      Lancet. 2008;371:126-134.                              with lower tidal volumes as compared with traditional tidal
                    7. Labeau SO, Van de Vyver K, Brusselaers N, et al. Prevention   volumes for acute lung injury and the acute respiratory distress
                      of ventilator-associated pneumonia with oral antiseptics: a   syndrome. N Engl J Med. 2000;342:1301-1308.
                      systematic review and meta-analysis. Lancet Infect Dis. 2011;11:     19. Kallet RH, Campbell AR, Dicker RA, et al. Work of breathing
                      845-854.                                               during lung-protective ventilation in patients with acute lung
                    8. Ranieri VM, Suter PM, Tortorella C, et al. Effect of mechanical   injury and acute respiratory distress syndrome: a comparison
                      ventilation on inflammatory mediators in patients with acute   between volume and pressure-regulated modes.  Respir Care.
                      respiratory distress syndrome: a randomized controlled trial.   2005;50:1623-1631.
                      JAMA. 1999;282:54-61.                                20. Nassar BS, Collett ND, Schmidt GA. The flow-time waveform
                    9. Neto AS, Cardoso SO, Manetta JA, et al. Association between   predicts respiratory system resistance and compliance.  J Crit
                      use of lung-protective ventilation with lower tidal volumes    Care. 2012;27:418.e7-418.e14.
                      and clinical outcomes among patients without acute respira-    21. Pohlman MC, McCallister KE, Schweickert WD, et al. Excessive
                      tory distress  syndrome:  a  meta-analysis.  JAMA.  2012;308:   tidal volume from breath stacking during lung-protective venti-
                      1651-1659.                                             lation for acute lung injury. Crit Care Med. 2008;36:3019-3023.
                   10. Futier E, Constantin J-M, Paugam-Burtz C, et al. A trial of intra-    22. Marini JJ, Rodriguez RM, Lamb V. The inspiratory workload
                      operative low-tidal-volume ventilation in abdominal surgery. N   of patient-initiated mechanical ventilation. Am Rev Respir Dis.
                      Engl J Med. 2013;369:428-437.                          1986;134:902-909.
                   11. Levine S, Nguyen T, Taylor N, et al. Rapid disuse atrophy of     23. Esteban A, Frutos F, Tobin MJ, et al. A comparison of four
                      diaphragm fibers in mechanically ventilated humans. N Engl J   methods of weaning patients from mechanical ventilation.
                      Med. 2008;358:1327-1335.                               N Engl J Med. 1995;332:345-350.












          Section04-O-ref.indd   1                                                                                  1/21/2015   11:23:15 AM
   741   742   743   744   745   746   747   748   749   750   751