Page 144 - Product Catalogue_v2.0
P. 144
TSA PM700
Specifications
Sensitivity Gamma: Will detect 3g HEU or 0.08g 239 Pu when tested in
accordance with ASTM Standard C 1236 for Category III*
monitors. *For neutron detection please contact
Neutron*: will detect 120g of 99% shielded 239 Pu based soley on your sales representative to determine
neutron detection. availabilty and quantity of He 3 tubes.
Detectors Gamma: Two 35 h x 10 w x 1.5 d in. (88.9 x 25 x 3.8 cm) organic
plastic scintillator detctors per pillar; provides approximately *ASTM Standard C 1236 and 1169 are
2,080 in 3 (35.4 liters) of detector volume per system. available for purchase from The American
Standard Gamma and Neutron: Two 35 h x 10 w x 1.5 d in. (88.9 Society for Testing and Materials, 100
x 25 x 3.8 cm) organic plastic scintillator detectors and one 2 in. Barr Harbor Drive, West Conshohocken,
diameter x 36 in. (5 x 91 cm) He 3 neutron detector per pillar The PA 19428 (610) 832-9585
scintillator detectors are shielded on four sides with 0.375 in. (10
mm) of lead.
High Sensitivity Gamma and Neutron: Two 30 h x 6 w x 1.5 d in. With continual development of our
(76.2 x 15.2 x 3.8 cm) organic plastic scintillator detectors and products Rapiscan Systems reserves the
two 2 in. diameter x 36 in. (5 x 91 cm) He 3 neutron detectors per right to amend specifications without
pillar The scintillator detectors are shielded on four sides with notice. Product pictures are for general
0.375 in. (10 mm) of lead. reference. Please note that due to US
laws and regulations, not all Rapiscan
Alarm Level SPRT for neutron, N* sigma for gamma entered from the products are available for sale in all
numeric keypad countries without restriction. Please
contact your Rapiscan Systems sales
False Alarm Rates Typically less than 1 in 1,000 passages, as tested in accordance representative for more information.
with ASTM Standard C 1169*
Alarm Indication Gamma alarms are indicated by a red strobe light on the master
pillar. High and low faults along with other fault conditions are
indicated by an amber light. Neutron alarm is indicated by a RAPISCAN RADIATION DETECTION
blue strobe light PRODUCT LINE HEADQUARTERS
14000 Mead Street
Display Alphanumeric LCD, 4 lines x 16 characters Longmont, Colorado 80504
Communications RS-232 Serial Port and Ethernet communications capabilities UNITED STATES of AMERICA
Tel: +1 970-535-9949
Data Storage 256k bytes of flash memory is used to store average hourly Fax: +1 970-535-3285
background and alarm data.
AMERICAS, CARIBBEAN
Power Requirements 90 - 250 Vac, 47 - 63 Hz, less than 100 VA
2805 Columbia Street
Battery Life Greater than 8 hours normal operation Torrance, California 90503
UNITED STATES of AMERICA
Dimensions 84 h x 26 w x 8 d in. (214 x 66 x 20 cm) Tel: +1 310-978-1457
Typical Pillar Spacing 35 in. (889 mm) Fax: +1 310-349-2491
Weight Gamma: ~ 400 lb (182kg) per pillar EUROPE, MIDDLE EAST, AFRICA
Neutron: ~600 lb (273kg) per pillar X-Ray House
Bonehurst Road
Environmental -4° to 122° F (-20° to 50°C) Salfords
Standards Surrey RH1 5GG
UNITED KINGDOM
Tel: +44 (0) 870-7774301
Fax: +44 (0) 870-7774302
Definitions ASIA
240 Macpherson Road
Gamma Detection - For the detection of ionizing radiation. #07-01 Pines Industrial Building
Singapore 348574
Neutron Detection - Typically used to detect Special Nuclear Materials (SNM). SINGAPORE
Gamma and Neutron Detection - For full spectrum detection capabilities. Tel: +65-6846-3511
Fax: +65-6743-9915
Options
EMAIL
Remote Alarm Panel sales@rapiscansystems.com
TSA RAVEN™ Communications Software
WEB
Wireless Output Capabilities www.rapiscansystems.com
Additional Lead Shielding
Rapiscan Systems is
ISO 9001:2008 Certified
ONE COMPANY - TOTAL SECURITY www.rapiscansystems.com
TSA PM700-A 081513