Page 22 - Chest Tube With Under-water Seal Drainage
P. 22

CikguOnline
    CikguOnline











                                           No.                                                          Procedure


                                            7.           Maintain tube patency of the drainage system:


                                                           7.1 check and ensure all connection are secured

                                                                    inspect drainage tube for kinks or loops or dangling  below
                                                           7.2
                                                                    the  entry  level  of  the drainage system

                                                                    coil   the   drainage   tubing  next   to  the   client, ensuring
                                                           7.3
                                                                    enough  slack  for  the client  to turn or move

                                                                    inspect the air vent in the system periodically to make
                                                           7.4
                                                                    sure it not occluded


                                                                    avoid  any  forceful manipulated  of  the tube  eg: milking
                                                           7.5
                                                                    or stripping the chest tubing

                                                                    observe  for  the  dislodgment  of  the  tube  and remedy
                                                           7.6
                                                                    the problem promptly
   17   18   19   20   21   22   23   24   25   26   27