Page 358 - 3rd issue
P. 358

intelligent

                                Jumper Wires

Description   Plain solid annealed copper conductor, solid PE or PVC insulated, tow insulated conductors are
              twisted together with short lay to from a pair according to Egyptian local standard spec. TC 113
Construction  also can be manufacturing according to customer specification.
Applications
              copper conductor.
              PVC or PE insulation.

              The jumber wires are used generally in outdoor cabinets forcross connections between primary
              and secondary terminal block also in main distribution frame in exchange buildings.

                         Dimensions and standard packing

Product-Code  Cable Size        Approx. outer            Approx. Weight     Shipping lengh  Packing
              Pair Count          diameter                      kg               Meter
              No. x mm               mm                                                       Coil
                                                                                              Coil
D03P000105    2 x 0.5           2.1                      0.6                100
D04P000105    2 x 0.6           2.4                      0.8                100

                       Electrical and transmission characteristics

1- Loop resistance at 20oC.     for both sizes
	 Max. 192 ohm / Km for 0.5 mm  for size 0.5 mm
                                for size 0.6 mm
	 Max. 131 ohm / Km for 0.6 mm
1.1 Resistance unbalance
	 Max. average		 1.5 	
	 Max. individual		 5	
	 Max. individual		 4	

2- Insulation Resistance
	 The insulation resistance at 20oC shall not less than
	 500 mega ohm Km.

3- The tensile strength of conductor is max. 26 kg/mm2 and min. 20 kg/mm2.

4- Mutual capacitance at 800 Hz Max. 100 nf/km.

                                                                                       We own the power