Page 373 - 3rd issue
P. 373

PE OUTER SHEATH                                                                     intelligent
CABLE MARKING
                  Black PE sheath is extruded over the aluminum tape. Due to the process-heat, both
                  elements are perfectly bonded together providing a barrier against the penetration
                  of moisture. The thickness of the outer sheath is as shown in table (4) column (2).

                  CABLES size / No. Of pairs          Nominal Outer sheath thickness (mm)

                                  10"                                        1.4
                                  20"                                        1.4
                                  30"                                        1.6
                                  50"                                        1.6
                                 100"                                        1.8
                                 150"                                        1.8
                                 200"                                        1.8
                                 250"                                        1.8
                                 300"                                        1.8
                                 400"                                         2
                                 500"                                         2
                                 600"                                         2

                  •	 Each length of cable has a longitudinal printing on the sheath surface indicating the
                        manufacturer

                  •	 GIZA CABLE INDUSTREIS, the month/year of manufacture, type of cables, number of
                        pair/conductor diameter, contract No. and running length.

                  Example:
                  For 100 pair " GIZA CABLE INDUSTREIS 100 x 2 x 0.6 mm Order NO. TC450 (YEAR)
                  (METER)”

                  The length shall be marked at regular interval of one meter along the regular.
                  The color of marking will be white.

CABLE ELECTRICAL      Parameters              Unit    Nominal Values
CHARACTERISTICS.
                   Conductor Dimensions         mm                0.6
                                                 /km              130
                  Loop resistance at 20 oC     nf/km              ≤50

                   Mutual Capacitance @       G .km                10
                             800 HZ             volt              225

                  Insulation Resistance @
                  Temperature = 20 oC &
                  Testing voltage 500 VDC
                    Rated Voltage (peak)