Page 129 - L . V S W I T C H G E A R
P. 129
intelligent
Features ͻ KīĞƌƐ ϯͲ ĂŶĚ ϰͲƉŽůĞ ǀĞƌƐŝŽŶƐ ƚŽ ƐƵƉƉŽƌƚ ǁŽƌůĚǁŝĚĞ ĂƉƉůŝĐĂ-
ƟŽŶ
ͻ /ŶĐůƵĚĞƐ ŚŝŐŚ ŝŶƚĞƌƌƵƉƟŶŐ ƌĂƟŶŐƐ ĨƌŽŵ ϭϴ͘͘͘ϭϬϬ Ŭ ŝŶ Ă ĐŽŵ-
pact device
CerƟĮcaƟons ͻ KīĞƌƐ Ă ǁŝĚĞ ƌĂŶŐĞ ŽĨ ŽƉĞƌĂƟŶŐ ŵĞĐŚĂŶŝƐŵƐ ƚŽ Įƚ Ă ǀĂƌŝĞƚLJ
ŽĨ ƉĂŶĞů ĐŽŶĮŐƵƌĂƟŽŶƐ
ͻ CCC
ͻ CE Marked ͻ WƌŽǀŝĚĞƐ ŐƌĞĂƚĞƌ ĐƵƐƚŽŵŝnjĂƟŽŶ ŝŶ ƚƌŝƉ ƵŶŝƚƐ
ͻ ^ ĞƌƟĮĞĚ ͻ KīĞƌƐ Ă ǁŝĚĞ ƌĂŶŐĞ ŽĨ ĂĐĐĞƐƐŽƌŝĞƐ ĨŽƌ ŐůŽďĂů ĂǀĂŝůĂďŝůŝƚLJ
ͻ UL Listed ͻ ƉƉƌŽǀĞĚ ĨŽƌ ŐůŽďĂů ĂƉƉůŝĐĂƟŽŶ͗ h>͕ ^ ͕ ͕ ĂŶĚ / ƉĞƌĨŽƌ-
ͻ ^ƵŝƚĂďůĞ ĨŽƌ ƵƐĞ ǁŝƚŚ / ϯ DŽ- ŵĂŶĐĞ ŝŶƚĞƌƌƵƉƟŶŐͬďƌĞĂŬŝŶŐ ĐĂƉĂĐŝƚLJ
tors (IEC 60034-30) ͻ KīĞƌƐ ĐƵƌƌĞŶƚͲůŝŵŝƟŶŐ ŽƉƟŽŶ ;,͕ :͕ ĂŶĚ < ĨƌĂŵĞƐͿ ƚŚĂƚ ƉƌŽ-
ͻ ^ƚĂŶĚĂƌĚƐ ŽŵƉůŝĂŶĐĞ vides half-cycle interrupt to limit let-through energy
ͻ ^ ϮϮ͘Ϯ͕ EŽ͘ ϱ
ͻ IEC 60947-2
ͻ UL489
Product Specifi cations
Note: the following catalog numbering scheme is provided for reference as to the extent of the product selection.
For additional selection information, consult publication 140G-SG001. For selectivity information consult publication
140G-TD050.
140G – HC 6 C 3 – C60 – SD – AA
_______ _____________________ _____ _____ _____
a b c d e f g g
a b c d
Bulletin Number Frame/Rating Interrupting Rating/Breaking Protection Type
Capacity (based on Ic at 480V)
Code Description Code Description Code Description
Code Description
Global Molded Case HC 125A C Fixed thermal/fi xed magnetic
140G
Circuit Breaker 6 65 kA
JC 250A F Adjust thermal/adjust magnetic
0 100 kA
KC 400A H Electronic LSI – long, short, instant
T Trip unit
I Electronic LSIG – long, short instant
and ground fault
e f
Electronic LSIG – MM long, short instant,
No. of Poles Current Range K ground fault and maintenance mode
(K-frame only)
Code Description H- and J-Frame
X Breaker frame
3 3 poles Code Description
C e.g., C30 = 30 A
g
D e.g., D16 = 160 A
Factory Installed Internal Options (1)
Blank Frame only
Shunt Trip and Undervoltage Release Units Auxiliary and Alarm Contacts, Trip
K-Frame MCCBs
Code Description Code Description
Code Description
SJ Shunt trip, 24…30V AC/DC KA (HJ) 1 aux. contact, 250V
D30 e.g., 300 A
SK Shunt trip, 48…60V AC/DC AA 1 aux., 1 alarm contact, 250V
D40 e.g., 400 A
SD Shunt trip, 110…127V AC; 110…125V DC BA (HJ) 2 aux., 1 alarm contact, 250V
Blank Frame only
SA Shunt trip, 220…240V AC; 220…250V DC CA (K) 3 aux., 1 alarm contact, 250V
SB Shunt trip, 380…440V AC DA (HJ) 1 trip unit alarm contact, 250V
SC Shunt trip, 480…525V AC FB 2 aux. contacts, 400V
Consult the publications listed below UJ Undervoltage release, 24…30V AC/DC AB 1 aux., 1 alarm contact, 400V
for detailed let-through and current curves. UR Undervoltage release, 48V AC/DC KJ (HJ) 1 aux. contact, 24V
Undervoltage release, 110…127V AC;
Let-Through lP Curve UD AJ (HJ) 1 aux., 1 alarm contact, 24V
kA Voltage 110… 125V DC
Energy Curve Number
Undervoltage release, 220…240V AC;
UA DJ (HJ) 1 trip unit alarm contact, 24V
65 480V 140G-TD056A-EN-P 140G-TD052A-EN-P 220… 250V DC
100 480V 140G-TD055A-EN-P 140G-TD051A-EN-P UB Undervoltage release, 380…440V AC CJ (K) 3 aux., 1 alarm contact, 24V
65 600V 140G-TD058A-EN-P 140G-TD054A-EN-P UC Undervoltage release, 480…525V AC
100 600V 140G-TD057A-EN-P 140G-TD053A-EN-P No Digit No selection
(1) Select up to two internal options: 1 for left side mounting (shunt trip or undervoltage release), 1 for right (auxiliary or alarm contact).
(HJ) H- and J-frame only.
(K) K-frame only.