Page 129 - L . V S W I T C H G E A R
P. 129

intelligent





                                  Features              ͻ  KīĞƌƐ ϯͲ ĂŶĚ ϰͲƉŽůĞ ǀĞƌƐŝŽŶƐ ƚŽ ƐƵƉƉŽƌƚ ǁŽƌůĚǁŝĚĞ ĂƉƉůŝĐĂ-
                                                           ƟŽŶ
                                                        ͻ  /ŶĐůƵĚĞƐ ŚŝŐŚ ŝŶƚĞƌƌƵƉƟŶŐ ƌĂƟŶŐƐ ĨƌŽŵ ϭϴ͘͘͘ϭϬϬ Ŭ   ŝŶ Ă ĐŽŵ-
                                                           pact device
                 CerƟĮcaƟons                            ͻ  KīĞƌƐ Ă ǁŝĚĞ ƌĂŶŐĞ ŽĨ ŽƉĞƌĂƟŶŐ ŵĞĐŚĂŶŝƐŵƐ ƚŽ Įƚ Ă ǀĂƌŝĞƚLJ
                                                           ŽĨ ƉĂŶĞů ĐŽŶĮŐƵƌĂƟŽŶƐ
                 ͻ  CCC
                 ͻ  CE Marked                           ͻ  WƌŽǀŝĚĞƐ ŐƌĞĂƚĞƌ ĐƵƐƚŽŵŝnjĂƟŽŶ ŝŶ ƚƌŝƉ ƵŶŝƚƐ
                 ͻ   ^   ĞƌƟĮĞĚ                         ͻ  KīĞƌƐ Ă ǁŝĚĞ ƌĂŶŐĞ ŽĨ ĂĐĐĞƐƐŽƌŝĞƐ ĨŽƌ ŐůŽďĂů ĂǀĂŝůĂďŝůŝƚLJ
                 ͻ  UL Listed                           ͻ   ƉƉƌŽǀĞĚ ĨŽƌ ŐůŽďĂů ĂƉƉůŝĐĂƟŽŶ͗ h>͕  ^ ͕    ͕ ĂŶĚ /   ƉĞƌĨŽƌ-
                 ͻ  ^ƵŝƚĂďůĞ ĨŽƌ ƵƐĞ ǁŝƚŚ / ϯ DŽ-          ŵĂŶĐĞ ŝŶƚĞƌƌƵƉƟŶŐͬďƌĞĂŬŝŶŐ ĐĂƉĂĐŝƚLJ
                    tors (IEC 60034-30)                 ͻ  KīĞƌƐ ĐƵƌƌĞŶƚͲůŝŵŝƟŶŐ ŽƉƟŽŶ ;,͕ :͕ ĂŶĚ < ĨƌĂŵĞƐͿ ƚŚĂƚ ƉƌŽ-
                 ͻ  ^ƚĂŶĚĂƌĚƐ  ŽŵƉůŝĂŶĐĞ                   vides half-cycle interrupt to limit let-through energy
                 ͻ   ^ ϮϮ͘Ϯ͕ EŽ͘ ϱ
                 ͻ  IEC 60947-2
                 ͻ  UL489


                  Product Specifi cations
                  Note: the following catalog numbering scheme is provided for reference as to the extent of the product selection.
                  For additional selection information, consult publication 140G-SG001. For selectivity information consult publication
                  140G-TD050.

                   140G    –   HC    6    C    3    –   C60   –   SD  –   AA
                    _______          _____________________             _____         _____        _____
                     a          b    c    d    e         f       g       g
                            a                   b                    c                            d
                        Bulletin Number     Frame/Rating    Interrupting Rating/Breaking     Protection Type
                                                            Capacity (based on Ic at 480V)
                    Code    Description   Code  Description                        Code           Description
                                                            Code     Description
                          Global Molded Case  HC  125A                              C        Fixed thermal/fi xed magnetic
                    140G
                            Circuit Breaker                  6         65 kA
                                           JC     250A                              F       Adjust thermal/adjust magnetic
                                                             0        100 kA
                                           KC     400A                              H      Electronic LSI – long, short, instant
                                                             T        Trip unit
                                                                                    I      Electronic LSIG – long, short instant
                                                                                                and ground fault
                          e                  f
                                                                                         Electronic LSIG – MM long, short instant,
                       No. of Poles     Current Range                               K     ground fault and maintenance mode
                                                                                                 (K-frame only)
                    Code  Description   H- and J-Frame
                                                                                    X            Breaker frame
                     3     3 poles   Code   Description
                                      C    e.g., C30 = 30 A
                                                                                     g
                                      D    e.g., D16 = 160 A
                                                                          Factory Installed Internal Options (1)
                                     Blank   Frame only
                                                           Shunt Trip and Undervoltage Release Units  Auxiliary and Alarm Contacts, Trip
                                        K-Frame MCCBs
                                                         Code           Description       Code       Description
                                     Code   Description
                                                          SJ       Shunt trip, 24…30V AC/DC  KA (HJ)  1 aux. contact, 250V
                                      D30    e.g., 300 A
                                                          SK       Shunt trip, 48…60V AC/DC  AA  1 aux., 1 alarm contact, 250V
                                      D40    e.g., 400 A
                                                          SD   Shunt trip, 110…127V AC; 110…125V DC  BA (HJ)  2 aux., 1 alarm contact, 250V
                                     Blank   Frame only
                                                          SA   Shunt trip, 220…240V AC; 220…250V DC  CA (K)  3 aux., 1 alarm contact, 250V
                                                          SB        Shunt trip, 380…440V AC  DA (HJ)  1 trip unit alarm contact, 250V
                                                          SC        Shunt trip, 480…525V AC  FB    2 aux. contacts, 400V
                  Consult the publications listed below   UJ    Undervoltage release, 24…30V AC/DC  AB  1 aux., 1 alarm contact, 400V
                  for detailed let-through and current curves.  UR  Undervoltage release, 48V AC/DC  KJ (HJ)  1 aux. contact, 24V
                                                                Undervoltage release, 110…127V AC;
                              Let-Through   lP Curve      UD                               AJ (HJ)  1 aux., 1 alarm contact, 24V
                   kA Voltage                                          110… 125V DC
                             Energy Curve   Number
                                                                Undervoltage release, 220…240V AC;
                                                          UA                               DJ (HJ)  1 trip unit alarm contact, 24V
                   65  480V  140G-TD056A-EN-P  140G-TD052A-EN-P        220… 250V DC
                   100  480V  140G-TD055A-EN-P  140G-TD051A-EN-P  UB  Undervoltage release, 380…440V AC  CJ (K)  3 aux., 1 alarm contact, 24V
                   65  600V  140G-TD058A-EN-P  140G-TD054A-EN-P  UC  Undervoltage release, 480…525V AC
                   100  600V  140G-TD057A-EN-P  140G-TD053A-EN-P  No Digit  No selection
                                                        (1)  Select up to two internal options: 1 for left side mounting (shunt trip or undervoltage release), 1 for right (auxiliary or alarm contact).
                                                        (HJ)  H- and J-frame only.
                                                        (K)  K-frame only.


                                                                                                                       129