Page 152 - Catalogo Iluminacion Vial
P. 152

Especificaciones Ópticas






                                             2700 K                                 3000 K


                               0.8  Max=9243  [1.0=20000]  1.63 SDCM  F2700K  0.8  Max=4612  [1.0=20000]  0.61 SDCM  F3000K
                               0.7                                     0.7
                               0.6                                     0.6

              Distribución    Spectrum  0.5               x=0.4612  y=0.4163  Spectrum  0.5      x=0.4398  y=0.4040
                                                                       0.4
                               0.4
               espectral       0.3                                     0.3
                               0.2                                     0.2
                               0.1                                     0.1
                               0.0                                     0.0
                                 380      500    600    700    800      380      500    600    700    800
                                            Wavelength(nm)                          Wavelength(nm)
                                              -/+180                                 -/+180
                                     -120               120                  -120              120

                                               0                                      0
                                     -90                90                   -90               90
                                              500                                     400
              Diagrama de                     1000                                    800
             intensidad polar                 1500                                    1200
                                              2000                                   1600
                                              2500                                   2000
                                     -30                30                   -30               30
                                               0                                       0
                                                     UNIT: cd                               UNIT: cd
                                       AVERAGE BEAM ANGLE(50%): 20.3 DEG       AVERAGE BEAM ANGLE(50%): 25.5 DEG
                                           Planar Illuminance Curve               Planar Illuminance Curve
                                    E(LX)              MH=10m              E(LX)              MH=10m
                                    25                  C0/180             20                  C0/180
                                                        C90/270                                C90/270
                                   22.5                                    18
                                    20                                     16
                                   17.5                                    14
           Diagrama cartesiano      15                                     12
              de intensidad        12.5                                    10
                                    10                                      8
                                   7.5                                      6
                                    5                                       4
                                   2.5                                      2
                                    0  -25-  20  -15-  10  -5  05  10  15  20  25  0  -25-  20  -15-  10  -5  05  10  15  20  25
                                              Distance(m)                            Distance(m)
                                      Flux out: 111.5 lm                      Flux out: 195.3 lm







            Diagrama de haz





                                   Height     Eavg, Emax     Angle: 17.55deg     Diameter  Height     Eavg, Emax     Angle: 25.52deg     Diameter
                                   Note: The Curves indicate the illuminated area and the average   Note: The Curves indicate the illuminated area and the average
                                             illumination when the Luminaire is at different distance.            illumination when the Luminaire is at different distance.
   147   148   149   150   151   152   153   154   155   156   157