Page 215 - Catalogo Iluminacion Vial
P. 215

Especificaciones Ópticas


          10º


                                             2700 K                                 3000 K


                               0.8  Max=7402  [1.0=20000]  5.33 SDCM  F2700K  0.8  Max=7569  [1.0=20000]  1.71 SDCM  F3000K
                               0.7                                     0.7
                               0.6                                     0.6

              Distribución    Spectrum  0.5               x=0.4593  y=0.4080  Spectrum  0.5       x=0.4390  y=0.4054
                                                                       0.4
                               0.4
               espectral       0.3                                     0.3
                               0.2                                     0.2
                               0.1                                     0.1
                               0.0                                     0.0
                                 380      500    600    700    800      380      500    600    700    800
                                            Wavelength(nm)                          Wavelength(nm)
                                              -/+180                                 -/+180
                                     -120               120                  -120              120

                                              0                                       0
                                      -90               90                   -90               90
                                              5000                                    5000
              Diagrama de                     10000                                   10000
             intensidad polar                 15000                                   15000
                                              20000                                   20000
                                      -30     25000     30                   -30      25000    30
                                               0                                       0
                                                    UNIT: cd                                UNIT: cd
                                       AVERAGE BEAM ANGLE(50%): 12.3 DEG       AVERAGE BEAM ANGLE(50%): 12.1 DEG
                                           Planar Illuminance Curve               Planar Illuminance Curve
                                    E(LX)              MH=10m               E(LX)             MH=10m
                                    250                C0/180              250                 C0/180
                                                        C90/270                                C90/270
                                    225                                    225
                                    200                                    200
                                    175                                    175
           Diagrama cartesiano      150                                    150
              de intensidad         125                                    125
                                    100                                    100
                                    75                                      75
                                    50                                      50
                                    25                                      25
                                    0                                       0  -25-  20  -15-  10  -5  05  10  15  20  25
                                     -25-  20  -15-  10  -5  05  10  15  20  25
                                              Distance(m)                            Distance(m)
                                      Flux out: 636.2 lm                      Flux out: 640.7 lm






            Diagrama de haz






                                   Height     Eavg, Emax     Angle: 12.00deg     Diameter  Height     Eavg, Emax     Angle: 12.18deg     Diameter
                                   Note: The Curves indicate the illuminated area and the average   Note: The Curves indicate the illuminated area and the average
                                             illumination when the Luminaire is at different distance.            illumination when the Luminaire is at different distance.
   210   211   212   213   214   215   216   217   218   219   220