Page 253 - Catalogo Iluminacion Vial
P. 253

Especificaciones Ópticas






                                             2700 K                                 3000 K


                                0.8  Max=7728  [1.0=20000]  5.12SDCM  F2700K  0.8  Max=8382  [1.0=20000]  2.81SDCM  F3000K
                                0.7                                    0.7
                                0.6                                    0.6
              Distribución     Spectrum  0.5              x=0.4646  y=0.4114  Spectrum  0.5      x=0.4456  y=0.4069
                                                                       0.4
                                0.4
               espectral        0.3                                    0.3
                                0.2                                    0.2
                                0.1                                    0.1
                                0.0                                    0.0
                                 380      500   600    700    800        380     500    600    700    800
                                            Wavelength(nm)                          Wavelength(nm)
                                              -/+180                                 -/+180
                                     -120               120                  -120              120
                                              0                                       0
                                      -90               90                   -90               90
                                              3000                                    4000
              Diagrama de                     6000                                    8000
             intensidad polar                 9000                                    12000

                                              12000                                   16000
                                              15000                                   20000
                                      -30               30                   -30               30
                                               0                                       0
                                                    UNIT: cd                                UNIT: cd
                                       AVERAGE BEAM ANGLE(50%): 16.9 DEG       AVERAGE BEAM ANGLE(50%): 17.0 DEG
                                           Planar Illuminance Curve                Planar Illuminance Curve
                                    E(LX)             MH=10m                E(LX)             MH=10m
                                    150                C0/180              200                 C0/180
                                                       C90/270                                 C90/270
                                    135                                    180
                                    120                                    160
                                    105                                    140
           Diagrama cartesiano      90                                     120
              de intensidad         75                                     100
                                    60                                      80
                                    45                                      60
                                    30                                      40
                                    15                                      20
                                     0 -25-  20  -15-  10  -5  05  10  15  20  25  0 -25-  20  -15-  10  -5  05  10  15  20  25
                                              Distance(m)                            Distance(m)
                                      Flux out: 651.1 lm                      Flux out: 931.8 lm






            Diagrama de haz






                                   Height     Eavg, Emax     Angle: 17.02deg     Diameter  Height     Eavg, Emax     Angle: 16.73deg     Diameter
                                   Note: The Curves indicate the illuminated area and the average   Note: The Curves indicate the illuminated area and the average
                                             illumination when the Luminaire is at different distance.            illumination when the Luminaire is at different distance.