GLOSSARY                                                                                       GLOSSARY


 ESA Rank 3:             vi.   Composite wood and agrifiber products
 All marine park islands, buffer zones around ESA Rank 2 areas, catchment
 areas for water intakes, groundwater extraction areas (well fields), areas with   Particleboard, medium-density fiberboard  (MDF), plywood, wheatboard,
 erosion  risk  greater  than  150ton/ha./year,  areas  experiencing  critical  or   strawboard, panel substrates, and door cores
 significant coastal erosion and areas between 150-300 metres a.m.s.l.

                        vii.   Contract Drawing
 iv.   Detailed Environmental Impact Assessment (DEIA)
                               Contract drawing is part of the Contract Document that need to be submitted
 A study is required for ten different types of projects, which include:   by the successful tenderer. Contract Drawing consists of:

 a)  Steel mill.               a)   Presentation drawings and schedules for A3 technical proposal.
 b)  Pulp and paper mill.
 c)  Cement plant.             b)   Main drawings (readable with standard scale):
 d)  Coal-fired power plant.        -    Architectural main drawings.
 e)  Dams (hydroelectric and water supply).   -   Loaded plans.
 f)   Coastal land reclamation.
 g)  Incinerators (scheduled wastes and solid wastes, solid wastes disposal   c)   Room Data Documents:
 sites).                            -    Room data sheet.
 h)  Projects involving land clearance where more than 50% of the area has   -   Drawings - Room/Area Floor Plan and four (4) wall elevations.
 slope>25°.
 i)   Logging (>500 hectares).   d)   Exterior perspective drawings.

 It  is  to  be  noted  that  for  projects  in  Sabah  and  Sarawak,  specific  local
 legislation on EIA requirements needs to be adhered to.   viii.   Loaded Drawing

                               Loaded Drawing is part of the Contract Document that needs to be submitted
 v.   Industrialised Building System (IBS)      by the successful tenderer. Loaded Drawings reference manuals consist of
                               reference fixtures and fittings of coding, drawings, and dimensions.
 An Industrialised Building System (IBS) is defined as a construction technique
 that involves industrialised production of building elements or components and
 erection and assembly of these elements into the desired building structure   ix.   Medical & Non-Medical Equipment
 through mechanical means.  The  components manufactured in a controlled
 environment  (on  or  off-site),  transported,  positioned,  and  assembled  into   Equipment provided in the facilities by group are as below:
 structure with minimal additional site work.
                               a)   Group 1 – Fixed Equipment Related to M&E
 IBS aims to reduce dependency on foreign labour, lower wastages, fewer site   - Supply and install by the contractor as per contract document.
 materials, a cleaner environment, better quality, neater and safer construction   (e.g., sterilizers, mortuary equipment, dental unit, diagnostic imaging,
 sites, faster project completion, and lower total construction costs.   operating light, operating table, etc.)

 All IBS elements/components shall be locally manufactured or fabricated.   b)   Group 2 – Fixed Equipment Related to M&E
                                    - Supply by the Client and install by the contractor.
                                      (e.g., salvageable items from an existing hospital).



 GL-02                                                                                               GL-03
 2021 EDITION                                                  HEALTH FACILITY ARCHITECTURAL NEEDS STATEMENT   2021 EDITION                                                  HEALTH FACILITY ARCHITECTURAL NEEDS STATEMENT
   143   144   145   146   147   148   149   150