Page 63 - R2017 Final_BE Biomedical Curriculum and Syllabus - REC
P. 63

Department of BME, REC

               OUTCOMES:
               On completion of the course students will be able to
                   •  Write ALP Programme for fixed and Floating Point and Arithmetic
                   •  Interface different I/Os with processor
                   •  Generate waveforms using Microprocessors
                   •  Execute Programs in 8051
                   •  Explain the difference between simulator and Emulator


                BM17512                BIOMEDICAL INSTRUMENTATION LABORATORY                       L  T  P  C
                                                                                                   0  0  4  2

               OBJECTIVES:
                   •  Measurement of physiological parameters
                   •  Biochemical parameters measurement
                   •  Biosignal analysis
                   •  Biotelemetry unit

               LIST OF EXPERIMENTS:
                   1.  Acquisition of ECG signals using 3 channel and 12 channel ECG machine.
                   2.  Real time EEG Acquisition and Measurement of Evoked Potential.
                   3.  Recording of EMG and  Measurement of NCV
                   4.  Construction and testing of pre amplifier to acquire bio signal
                   5.  Measurement of Blood Flow Velocity using Ultrasonic blood flow Monitor
                   6.  Study of EMG /ECG Isolation amplifier using analog circuit
                   7.  Study of Galvanic Skin Resistance using GSR System
                   8.  Measurement of pH and conductivity.
                   9.  Study of biotelemetry Unit
                   10. To measure the blood pressure levels using Sphygmomanometer.
                   11. Simulation of ECG – detection of QRS complex and heart rate
                   12. Design a suitable filter for biosignal Acquisition

                                                                                        TOTAL: 60 PERIODS

               LAB REQUIREMENTS FOR A BATCH OF 30 STUDENTS:
                   1.  Multiparameter patient monitoring system: 1 No.
                   2.  EEG recorder with accessories for evoked studies: 1 No.
                   3.  ECG recorder: 1 No.
                   4.  EMG recorder: 1 No.
                   5.  PH meter, conductivity meter: 1 No.
                   6.  Blood flow measurement system using ultrasound transducer: 1 No.
                   7.  GSR measurement setup. : 1 No.
                   8.  Function Generators
                   9.  DSOs
                   10. Regulated Power supplies
                   11. Bread boards
                   12. IC 741

               OUTCOMES:
               On completion of the course students will be able to
                   •  Design amplifier circuits for Bio signal measurements.


               Curriculum and Syllabus | B.E Biomedical Engineering | R 2017                       Page 63