Air Distribution System




 1. Air Take-off: Air is received from generation system through air take-off for
 distribution. The air take-off is at the top of the main pipe to ensure
 condensate remains in the main pipe, water take off from beneath the pipe
 will flow into an automatic drain and the condensate will be removed when it
 reaches a low point .

 2. Auto Drain helps to drain out the remaining water produced from
 condensation and must be placed at its lowest point to prevent water from
 remaining in the tube.



 3. Air Service Unit is a combination of Filter – Regulator –
 Lubricator (FRL). Air service unit conditions the compressed
 air to ensure the air is clean at optimum pressure and if
 required, lubricant is added to extend the life of those
 Air distribution   pneumatic system components. The type of air service unit to

 system  be used is depending on application, it can be FRL or FR
 type.

                                               Figure X: Air service unit