Page 81 - Pneumatic ebook (2)_draft 13 sept 2021
P. 81

How to name a DCV?




                                 no. of ports in a box / No. of boxes– way, method of actuation, method of return DCV


       Box 2                     3/ 2– way NC pushbutton with spring return DCV
       (actuation               Box 1 (initial
       state)                   position)                                               Tips:

                                                                                        ❑ Label or port marking only at the initial
                         2
                                                                                           position.
                                                                                        ❑ The number of port at each box is the same
                                                                                        ❑ The normal position (normally open, NO &
                      1       3                                                            normally closed, NC) need to refer to the

                                                                                           port 1 of the initial position. This is only for
                                            Number of squares (boxes) = 2                  3/2 way DCV

                                            Number of ports in one box = 3
                                            method of actuation = push

                                            button

                                              method of return = spring





                                                               INTRODUCTION TO PNEUMATIC SYSTEM                                            36