TECHNICAL DATA
VALVE SPECIFICATIONS
CONTROL SYSTEMS
Maximum Distance From
Type of System Controller to Valve Elevation Restrictions
Pin Type (00) Hydraulic* with 4.8mm (0.19") Control 30.5m (100')
£
Tubing
£
Pin Type (00) Hydraulic* with 6.4mm (0.25") Control Tubing 61.0m (200')
Normally Open (01) with 4.8mm (0.19") Control Tubing 152.4m (500') Valve elevation should not exceed 7.6m (25') ABOVE or 21.3 (70')
BELOW controller elevation.
Normally Closed (08) Hydraulic with 4.8mm (0.19") 152.4m (500') Valve elevation should not exceed 0m (0') ABOVE or 21.3 (70')
Control Tubing BELOW controller elevation.
Normally Open (01) with 6.4mm (0.25") Control Tubing 304.8m (1000') Valve elevation should not exceed 7.6m (25') ABOVE or 21.3 (70')
BELOW controller elevation.
Normally Closed (08) Hydraulic with 6.4mm (0.25") 304.8m (1000') Valve elevation should not exceed 7.6m (25') ABOVE or 21.3 (70')
Control Tubing BELOW controller elevation.
Electric (06) Depends on variables NONE
• Voltage available
• Wire size
1
* - All hydraulic connections on Toro valves are ⁄4" insert type.
- Control line pressure must be equal to or greater than mainline pressure.
- Control line pressure range is 40 to 150 psi.
* * Minimum solenoid voltage required for reliable electric VIH operation is 19.5 V AC
£ - Maximum of one (1) valve per station on pin type systems.
CONVERSION INFORMATION SPRINKLER SPACING PRECIPITATION RATE FORMULAS
• All gallons per minute are shown in The Toro Company does not recommend ■ Square-spaced sprinklers in pattern:
U.S. designing for zero (0) mph wind
• To convert to imperial gallons per conditions. GPM of full-circle x 96.3
minute, multiply by 0.833 ■ Square Spacing (Spacing) 2
• To convert to liters per minute, No wind - 55% of diameter
multiply by 3.78 4 mph wind - 50% of diameter
• To convert pounds per square inch 6.4 kph wind - 50% of diameter ■ Triangular-spaced sprinklers in pattern:
(psi) to atmospheres, divide by 14.7 8 mph wind - 45% of diameter GPM of full-circle x 96.3
12.8 kph - 45% of diameter
• To convert pounds per square (Spacing) (0.866)
2
inch (psi) to kilograms per square ■ Triangular Spacing
centimeter (kg/cm²), divide by 14.22 No wind - 60% of diameter
4 mph wind - 55% of diameter
• To convert feet to meters, divide by 6.4 kph wind - 55% of diameter ■ Area and flow:
3.28
8 mph wind - 50% of diameter Total GPM of zone x 96.3
WINTERISING SPECIFICATIONS 12.8 kph - 50% of diameter
In freezing climates, valves should be ■ Single Row Spacing Total irrigated square feet of zone
properly winterised to prevent freeze- No wind - 50% of diameter
related damage. 4 mph wind - 50% of diameter ■ Single row: 6FDOORS
6.4 kph wind - 50% of diameter
8 mph wind - 45% of diameter GPM of full-circle x 96.3 6SDFLQJ
12.8 kph - 45% of diameter
(Spacing) (Scallop)
Design in consideration of the worst wind
conditions.
Valve-In-Head Activation Types
Electric Normally Open Check-O-Matic
• Pressure regulation feature at the • Individual sprinkler control for more • Maintains 11.3m(37’) elevation change
same pressure—regardless of elevation precise watering • Eliminates low-head drainage
changes • Hydraulic control capability with • Requires separate remote control valve
• Manual On-Off-Auto control at the sophisticated electronic/electric control
sprinkler systems
• Individual sprinkler control for more • Ideal for all dirty water applications—
precise watering irrigation water is not used for control
• Lightning resistant