Page 195 - SFR Chain Catalogue v.3.1
P. 195
检查及维修制度
Inspection and maintenance
检查及维修制度
1. ԮࠏܒႵཋaᆞಒ֥߁
ູਔ৽Ԯ༢ᆞӈᄎྛđྶؓ৽Ԯ
2. Ԯ༢ᇏۄടࠣၩຓؿള
ልᇂࣉྛᆞಒطࠣൈ֥ົbೂᇠa
3. ߊ֥৽่ބ৽сྶ৫ࠧ۷ߐ
ᇠӵࠣᆦቖa৽่ა৽ၛࠣ߁ൔ
4. ଈဒᆣ֥৽่ބ৽ႋھ۷ߐ
֥࿊ᄴࠣ༢֥νል൞ᆞಒ֥bପહđ
5. ৽ႋھᅳᆞ
ൈߎႋھࡹ৫၂ཛົᇅ؇đၛಒЌ
6. ৽่ႋൡ֥֒ᅦࣅ
༢ᆞӈ۽ቔğ
7. ٝልᇂԩႿਅݺሑνልᆞಒ
µḤ৽Ԯልᇂႋᄝ൮Ցᄎሇ͂̽͵ުࣉྛҰb
ḤḤḤḤՎުđؓႿӵ൳ᇗԊࠌᄛހࠇ۽ঃذਜ֥৽Ԯđၛުႋھૄ۽ቔ͂̽̽͵ުࣉྛҰb
Inspection and maintenance
In order to run the chain transmission system 1. Effective and correct lubrication of the transmission drive
normally, the chain transmission parts must be 2. No interferences or obstructions in the transmission drive
properly and timely maintained. The choice of
shafts, bearings, chain and sprockets, as well as 3. Damaged chain or sprockets must be replaced immediately
the type of lubrication and the installation of the 4. Seriously worn-out chain or sprockets must be replaced immediately
drive must be all correct. At the same time, an 5.
effective and regular maintenance system shall The sprockets must be aligned
be established to ensure the smooth functioning 6. The chain must be properly stretched (tensioned)
and maximum lifespan of the drive and its parts.
7. Protection casings and devices shall be in good condition and properly installed
µḤ͡͵ͲḤͰ͵ͮͶͻḤͱͿͶͲḤ͵ͮḤͯͲḤͶͻͽͲͰͲͱḤͮͳͲͿḤ͵ͲḤͳͶͿḤ͂̽Ḥ͵ͼͿḤͼͳḤͼͽͲͿͮͶͼͻ̻
ḤḤḤḤ͎ͳͲͿḤ͵̹ͮḤͳͼͿḤͰ͵ͮͶͻḤͱͿͶͲḤͯͷͲͰḤͼḤͲͲͿͲḤ͵ͼͰḤͼͮͱͶͻʹḤͼͿḤͽͼͼͿḤ΄ͼͿͶͻʹḤͰͼͻͱͶͶͼͻ̹Ḥ͵ͲḤͶͻͽͲͰͶͼͻḤ͵ͼͱḤͯͲḤͽͲͿͳͼͿͺͲͱḤͮͳͲͿḤ͂̽̽Ḥ͵ͼͿḤͼͳḤͼͽͲͿͮͶͼͻ̻
www.sfrchain.com 178