Page 50 - ENGINEERING REVIEW NOVEMBER 2022_Neat
P. 50

ENGINEERING
           REVIEW                INSIGHT


           Diagnosis and Resolution of


           Compressor Vibrations and Cooling Fan


           Failure in an Industrial Plant





                crew compressors form a critical
                asset in the process industries,
           Swherein most manufacturing
           processes are aided by compressed
           air. Being a part of the positive
           displacement family, the periodic flow
           oscillations result in fluctuating dynamic     Fig. Failure symptoms in Cooling Fan assembly & parts
           forces leading to noise and vibrations
           in a screw air compressor. This article   are equipped with bell-mouths for the   Investigative teardown analysis of
           explains an investigation where a   efficient and quiet operation of the   the stator-rotor rub pattern combined
           compressor exhibits high vibrations   compressor. In the illustrated case, the   with the bearing bore wear pattern
           and noise levels leading to failure of the   cooling fan failures led to the shutdown   hypothesizes conical whirling as a
           axial fans in the cooling system, along   of the compressor, thereby stalling the   possible cause for premature failure.
           with a sustainable, robust solution to   plant operation.             The stator-rotor rub due to excessive
           assure uptime and reliability for the                                 dynamic deflection led to insulation
           uninterrupted operation of the plant.  Prime causes for the Cooling Fan   peeling off in the drive end side of the
             The screw air compressor under   Vibrations and Abnormal Noise      motor fan, supporting the hypothesis of
           discussion delivers compressed air at   There are various reasons for possible   the conical whirling of the impeller.
           2500m3/h at a pressure of 7bar as   malfunctioning of a cooling fan, viz.
           per the requirements of the specific   wear and tear, excessive system   Investigative diagnostics for
           industrial application. The motor and   resistance, accelerated fouling   excessive vibrations in Compressor
           the compression element (airend)   of coolers from the installation   Numerical analysis and experimental
           are coupled by a torsional resilient   environment, surges in supply voltages,   verification
           coupling that is dynamically isolated to   improper maintenance of coolers, etc.   The dynamic characteristics of the fan
           minimize the transmission of structural   In this case, the cooling fan exhibits   subassembly were analysed through a
           excitation forces to other subsystems   high vibrations and abnormal noises   numerical simulation of the complete
           of the compressor. The outer rotor   resulting from worn-out failure and   cooling system and the subassembly of
           axial fans in the parallel configuration   anomaly in vibration levels.  the fan, motor, suspension and support
                                                                                 structure. Experimental verification and
                                                                                 updating of the numerical model were
                                                                                 achieved through an instrumented
                                                                                 impulse generator and piezoelectric
                                                                                 accelerometers mounted on the stator
                                                                                 hub. The fundamental bouncing and
                                                                                 tilting modes were established for
                                                                                 possible excitation from residual
                                                                                 unbalance. Detailed analysis indicates
                                                                                 that the dynamic behaviour of the
                                                                                 subassembly possesses adequate
              Fig. a) Illustration of compressor Package    b) Cooling system subassembly.  design margins for safe operation.



          46   |  NOVEMBER 2022
   45   46   47   48   49   50   51   52   53   54   55