Page 17 - PONPE Catalogs 2022
P. 17

PROTRONICS CO.,LTD.
          8                          Measuring Instruments Store
                                     Line: @ponpe / Facebook: »¹à» / Tel: 02-5316293,5-6 / Website: www.ponpe.com


                 PONPE 590


         Specifications

                       pH             0.00 ~ 14.00
            Range      ORP            -1000mV ~ 1000mV
                       Temp           0.0 ~ 50.0°C(NTC10K)
                       pH             0.01
          Resolution   ORP            1mV
                       Temp           0.1°C
                       pH             0.1
          Accuracy     ORP            ≤±5mV (Electronic component)
                       Temp           ±0.5°C
                       Characteristics  Isolated, fully adjustable, reversible
          (4~20) mA    Loop resistance  500¹ (Max), DC 24V
                       Accuracy       ±0.1mA
            Control    Electrical contacts  Double relay SPST-NO, return model
             contact   Loop capacity  AC 220V / AC 110V 2A; DC 24V 2A
            Working    Temperature    (0~50) °C
           environment  Humidity      £85%RH (none condensation)

                                                                 Option  («×éÍà¾ÔèÁ)





                         M   C7   20                                               MI150
                         MC720



























         Specifications                                          Specifications
         pH Range: 0.0 - 14.0 pH                                pH Range: -2.00 to 16.00 pH
         Resolution: 0.1 pH                                     Temp range: -20.0 to 120.0°C
         Accuracy: ±0.2 pH                                      pH Resolution: 0.01 pH
         Calibration: Manual 2 points                           Temp Resolution: 0.1°C / 0.1 °F
         Alarm: Active when reading is higher or lower          pH Accuracy: ±0.01 pH
 ORP: -1000 ~1000mV, ±1mV  than set point                       Temp Accuracy: ±0.4°C / ±0.8°F
         Dosing Contact: 1 power plug for CO2 dosing            pH Typical EMC Deviation: ±0.02 pH
         pH electrode: MA911B/2 (included)                      Temp Typical EMC Deviation: ±0.4°C / ±0.8°F
         Environment: 0 to 50 oC / 32 to 122 oF; max RH 95%     O set Calibration: ±1 pH
         Power Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz  Slope Calibration: from 80 to 108%

              38/40-41 ËÁÙ‹·Õè 3 ¶¹¹ÅÓÅÙ¡¡Ò —µœ§†»†—
         ÍÓàÀÍÅÓÅÙ¡¡Ò ¨Ñ§ËÇÑ´»·ØÁ¸Ò¹Õ 12130                                                     ½…¤¸Å®ˆ¨²•…m³‚¤••m³ˆ
   12   13   14   15   16   17   18   19   20   21   22