         29                          Measuring Instruments Store
                                     Line: @ponpe / Facebook: »¹à» / Tel: 02-5316293,5-6 / Website: www.ponpe.com



     7XUELGLW\ 0HWHU                                    ½…¤¸Å®ˆ¨²•…¨³¢ƒ¹mš



                                                                        MI415






                                                        JTU     FTU (NTU/FTU)  SiO2 (mg/L)
                                                JTU     1           19            2.5
                                                FTU     0.053       1             0.13
                                                SiO2    0.4         7.5            1

                                                  Specifications

                                                Range : 0.00 to 50.00 FNU; 50 to 1000 FNU
                                                Resolution : 0.01 FNU; 1 FNU
                                                 Accuracy : ±0.5 FNU or ±5% of reading, whichever is greater
                                                Method : detection of scattered light
                                                Light Source : high emission infrared LED
                                                Light Detector : silicon photocell
                                                Environment : 0 to 50°C / 32 to 122°F; max RH 100%
                                                Battery Type : 1 x 9V
                                                Auto-o  : after 5 minutes of non-use
                                                Dimensions : 92 x 104 x 52 mm
                                                Weight : 380 g


          TB400                                PONPE 509TU
























         Specifications                                                          Specifications
         Turbidity Range (NTU): 0.00 to 50.00, 50 to 1000                       Range: 0~19.99NTU, 20~199.9NTU, 200~1000NTU
         Resolution: 0.01 NTU                                                   Resolution: 0.01, 0.1, 1NTU
         Accuracy: ±5% FS or ±0.5 NTU, whichever is greater                     Accuracy: ±3% <500NTU; ±5% >500NTU
         Light source: LED, 850nm                                               Response time: <10s
         Standard: Designed to meet ISO 7027                                    Operating: 0~50°C, <85% RH
         Response Time: <10 seconds                                             Sample: 10ml
         Dimensions: 6.1 x 3.0 x 2.4" (155 x 76 x 62mm)
         Weight: 11.3oz (320g)                                                  Data memory: 150 points
                                                                                Power: 4 x AAA battery
                                                                                Size: 70 x 135 x 65mm
                                                                                Weight: 168g