Page 182 - 3rd issue
P. 182
intelligent
0.6/1 (1.2) kV
Multicore Cables, with Stranded
Aluminum
Conductors XLPE Insulated and
PVC Sheathed
Description Aluminium conductor Binder tape PVC Sheathing
• Multicore cables of stranded Aluminium conductors are insulated with XLPE insulation, assembled together
and covered with an overall jacket of PVC compound.
• Cables are produced according to IEC 60502.
Application
• For outdoor and indoor installations in damp and wet locations. They are normally used for power
distribution in urban networks, in industrial plants, as well as in thermopower and hydropower stations.
Nominal Cross Max. Conductor Resistance Current Rating Approx. Approx
Sectional Area Overall Weight
Product-Code DC at AC at Laid direct in Laid in Ducts Laid in Free Diameter
mm2 20 OC 90 OC Ground A Air kg / km
A14X202UP A A mm
A15X202UP 10 rm Ω/km Ω/km 235
A16X202UP 16 rm 310
A17X202UP 25 rm Two Core Cables 450
35 rm 565
A14X203UP 3.0800 3.9500 57 48 55 13.8
A15X203UP 10 rm 1.9100 2.4500 74 58 73 15.8 250
A16X203UP 16 rm 1.2000 1.5400 97 75 97 18.8 330
A17X203UP 25 rm 0.8680 1.1130 128 106 120 21.0 460
35 rm 580
A14X204UP Three Core Cables
A15X204UP 10 rm 320
A16X204UP 16 rm 3.0800 3.9500 52 42 48 15.1 405
A17X204UP 25 sm 1.9100 2.4500 68 52 62 17.3 585
A18X204UP 35 sm 1.2000 1.5400 90 71 84 20.5 745
A19X204UP 50 sm 0.8680 1.1130 120 95 105 22.9 905
A20X204UP 70 sm 1260
A21X204UP 95 sm Four Core Cables 1565
A22X204UP 120 sm 1950
A23X204UP 150 sm 3.0800 3.9500 52 42 48 16.4 2405
A24X204UP 185 sm 1.9100 2.4500 68 52 62 18.9 2930
A25X204UP 240 sm 1.2000 1.5400 90 71 84 22.5 3725
300 sm 0.8680 1.1130 120 95 110 25.2 4625
0.6410 0.8220 145 110 136 26.5
0.4430 0.5690 175 140 168 30.8
0.3200 0.4110 210 165 205 33.5
0.2530 0.3250 235 190 236 37.6
0.2060 0.2650 265 215 278 42.1
0.1640 0.2120 290 240 315 47.1
0.1250 0.1630 340 280 378 52.9
0.1000 0.1310 390 325 446 58.5
Nominal Cross Max. Conductor Resistance Current Rating Approx. Approx
Sectional Area Laid in Ducts Overall Weight
Product-Code DC at AC at Laid direct in Laid in Free Diameter
mm2 20 OC 90 OC Ground A Air kg / km
A17X2R3UP A A mm
A18X2R3UP Ω/km Ω/km
A19X2R3UP
A20X2R3UP Four Core Cables with Reduced Neutral
A21X2R3UP
A22X2R3UP 35 sm 16 rm 0.8680/1.9100 1.1130/2.4500 120 95 110 23.6 670
A23X2R3UP 50 sm 25 sm
A24X2R3UP 70 sm 35 sm 0.6410/1.2000 0.8220/1.5400 145 110 136 25.3 830
A25X2R3UP 95 sm 50 sm
120 sm 70 sm 0.4430/0.8680 0.5690/1.1130 175 140 168 29.1 1120
150 sm 70 sm
185 sm 95 sm 0.3200/0.6410 0.4110/0.8220 210 165 205 33.0 1415
240 sm 120 sm
300 sm 150 sm 0.2530/0.4430 0.3250/0.5690 235 190 236 35.9 1770
0.2060/0.4430 0.2650/0.5690 265 215 278 39.7 2120
0.1640/0.3200 0.2120/0.4110 290 240 315 44.6 2590
0.1250/0.2530 0.1630/0.3250 340 280 378 49.9 3260
0.1000/0.2060 0.1310/0.2650 390 325 446 55.2 4065
The data is approximate an subjected to manufacturing tolerance. rm: round stranded
sm: sector stranded
Member Pioneer Holding
182