Page 185 - 3rd issue
P. 185
intelligent
0.6/1 (1.2) kV
Multicore Cables, with Stranded
Copper Conductors XLPE
Insulated and PVC Sheathed Copper Conductor Inner Sheathing
Steel Wire Armored
XLPE insulation SWA PVC Sheathing
Description
Binder tape ( Steel Wire Armoring)
• Multicore cables of stranded Copper conductors are insulated with XLPE compound,, assembled together,
armoured with steel wires and covered with an overall jacket of PVC compound.
• Cables are produced according to IEC 60502 or BS 5467.
Application
• For outdoor Installation in damp wet locations where mechanical damages are expected to occur.
Nominal Cross Max. Conductor Resistance Current Rating Approx. Overall
Sectional Area Approx Weight
Product-Code DC at AC at Laid direct in Laid in Ducts Laid in Free
20 OC 90 OC Ground Air Diameter
Ω/km Ω/km A mm kg / km
mm2 A A
C12X202HP 4.6100 5.8800 Two Core Cables 47 16.6 580
C13X202HP 4 rm 3.0800 3.9300 41
C14X202HP 6 rm 1.8300 2.3300 51 53 61 17.6 660
C15X202HP 10 rm 1.1500 1.4700 64 70
C16X202HP 16 rm 0.7270 0.9270 83 84 80 18.0 730
C17X202HP 25 sm 0.5240 0.6690 107 108
35 sm 140 135 106 20.0 925
168
Three Core Cables 37 140 24.1 1410
46 46
58 61 168 26.3 1715
76 76
C12X203HP 4 rm 4.6100 5.8800 98 103 42 17.2 650
C13X203HP 6 rm 3.0800 3.9300 130 122
C14X203HP 10 rm 1.8300 2.3300 158 51 18.3 755
C15X203HP 16 rm 1.1500 1.4700 Four Core Cables 37
C16X203HP 25 sm 0.7270 0.9270 46 46 69 19.3 825
C17X203HP 35 sm 0.5240 0.6690 58 61
76 76 90 21.5 1070
98 103
130 122 120 25.8 1620
158 145
185 180 147 28.2 1990
220 210
C12X204HP 4 rm 4.6100 5.8800 265 245 42 18.3 740
C13X204HP 6 rm 3.0800 3.9300 305 275
C14X204HP 10 rm 1.8300 2.3300 335 310 51 19.5 860
C15X204HP 16 rm 1.1500 1.4700 375 365
C16X204HP 25 sm 0.7270 0.9270 435 405 69 20.6 990
C17X204HP 35 sm 0.5240 0.6690 490
C18X204HP 50 sm 0.3870 0.4940 90 24.2 1450
C19X204HP 70 sm 0.2680 0.3430
C20X204HP 95 sm 0.1930 0.2480 122 27.8 1975
C21X204HP 120 sm 0.1530 0.1970
C22X204HP 150 sm 0.1240 0.1600 147 30.7 2465
C23X204HP 185 sm 0.0991 0.1290
C24X204HP 240 sm 0.0754 0.0990 184 33.1 3200
C25X204HP 300 sm 0.0601 0.0810
220 39.2 4645
273 42.9 5870
315 48.4 7555
375 53.1 8985
410 57.9 10760
488 64.1 13480
562 69.7 16215
Nominal Cross Max. Conductor Resistance Current Rating Approx. Approx
Sectional Area Laid in Ducts Overall Weight
Product-Code DC at AC at Laid direct in Laid in Free Diameter
mm2 20 OC 90 OC Ground A Air kg / km
C17X2R3HP A A mm
C18X2R3HP Ω/km Ω/km
C19X2R3HP
C20X2R3HP Four Core Cables with Reduced Neutral
C21X2R3HP
C22X2R3HP 35 sm 16 rm 0.5240/1.1500 0.6690/1.4700 158 122 147 28.9 2210
C23X2R3HP 50 sm 25 sm 0.3870/0.7270 0.4940/0.9270 185 145
C24X2R3HP 70 sm 35 sm 0.2680/0.5240 0.3430/0.6690 220 180 184 31.3 2860
C25X2R3HP 95 sm 50 sm 0.1930/0.3870 0.2480/0.4940 265 210
120 sm 70 sm 0.1530/0.2680 0.1970/0.3430 305 245 220 37.5 4240
150 sm 70 sm 0.1240/0.2680 0.1600/0.3430 335 275
185 sm 95 sm 0.0991/0.1930 0.1290/0.2480 375 310 273 41.2 5290
240 sm 120 sm 0.0754/0.1530 0.0990/0.1970 435 365
300 sm 150 sm 0.0601/0.1240 0.0810/0.1600 490 405 315 45.3 6475
375 50.5 8055
410 55.4 9735
488 60.3 11780
562 66.4 14435
The data is approximate an subjected to manufacturing tolerance. rm: round stranded
sm: sector stranded
Member Pioneer Holding 185