Page 197 - 3rd issue
P. 197
intelligent
0.6/1 (1.2) kV
Multicore Cables, with Stranded
Copper Conductors, XLPE
Insulated, Steel Tape Armored
and PVC Sheathed Copper conductor Inner Sheathing
tape ( Steel
Description XLPE insulation Binder STA PVC Sheathing
tape Armoring
)
• Multicore cables of stranded copper conductors are insulated with XLPE compound,, assembled together,
armoured with steel tape and covered with an overall jacket of PVC compound.
• Cables are produced according to IEC 60502
Application
• For outdoor Installation in damp wet locations where mechanical damages are expected to occur
Nominal Cross Max. Conductor Resistance Current Rating Approx. Approx
Sectional Area Overall Weight
Product-Code DC at AC at Laid direct in Laid in Ducts Laid in Free Diameter
mm2 20 OC 90 OC Ground A Air kg / km
C13X202IP A A mm
C14X202IP 6 rm Ω/km Ω/km 405
C15X202IP 10 rm 490
C16X202IP 16 rm Two Core Cables 655
C17X202IP 25 rm 935
35 rm 3.0800 3.9300 62 51 59 15.5 1185
C13X203IP 1.8300 2.3300 81 68 78 15.6
C14X203IP 6 rm 1.1500 1.4700 105 82 103 17.8 465
C15X203IP 10 rm 0.7270 0.9270 138 106 137 20.8 575
C16X203IP 16 rm 0.5240 0.6690 164 132 164 23.0 790
C17X203IP 25 rm 1105
35 rm Three Core Cables 1420
C13X204IP
C14X204IP 6 rm 3.0800 3.9300 56 44 49 16.2 555
C15X204IP 10 rm 1.8300 2.3300 74 59 67 17.1 720
C16X204IP 16 rm 1.1500 1.4700 96 74 88 19.3 975
C17X204IP 25 sm 0.7270 0.9270 127 100 120 22.5 1385
C18X204IP 35 sm 0.5240 0.6690 153 119 143 24.9 1775
C19X204IP 50 sm 2415
C20X204IP 70 sm Four Core Cables 3335
C21X204IP 95 sm 4815
C22X204IP 120 sm 3.0800 3.9300 56 44 49 17.4 5910
C23X204IP 150 sm 1.8300 2.3300 74 59 67 18.4 7195
C24X204IP 185 sm 1.1500 1.4700 96 74 88 20.9 8830
C25X204IP 240 sm 0.7270 0.9270 127 100 120 24.5 11285
300 sm 0.5240 0.6690 153 119 143 27.2 13835
0.3870 0.4940 185 145 178 30.1
0.2680 0.3430 220 180 225 34.6
0.1930 0.2480 265 210 268 39.7
0.1530 0.1970 305 245 310 43.8
0.1240 0.1600 335 275 352 48.7
0.0991 0.1290 375 310 404 53.7
0.0754 0.0990 435 365 483 60.0
0.0601 0.0810 490 405 562 65.5
Nominal Cross Max. Conductor Resistance Current Rating Approx. Approx
Sectional Area Laid in Ducts Overall Weight
Product-Code DC at AC at Laid direct in Laid in Free Diameter
mm2 20 OC 90 OC Ground A Air kg / km
A A mm
Ω/km Ω/km
Four Core Cables with Reduced Neutral
C17X2R3IP 35 sm 16 rm 0.5240/1.1500 06690/1.4700 153 119 143 25.6 1615
C18X2R3IP 50 sm 25 sm
C19X2R3IP 70 sm 35 sm 0.3870/0.7270 0.4940/0.9270 185 145 178 28.7 2160
C20X2R3IP 95 sm 50 sm
C21X2R3IP 120 sm 70 sm 0.2680/0.5240 0.3430/0.6690 220 180 225 33.1 2960
C22X2R3IP 150 sm 70 sm
C23X2R3IP 185 sm 95 sm 0.1930/0.3870 0.2480/0.4940 265 210 268 38.0 4280
C24X2R3IP 240 sm 120 sm
C25X2R3IP 300 sm 150 sm 0.1530/0.2680 0.1970/0.3430 305 245 310 42.1 5365
0.1240/0.2680 0.1600/0.3430 335 275 352 46.3 6355
0.0991/0.1930 0.1290/0.2480 375 310 404 51.2 7865
0.0754/0.1530 0.0990/0.1970 435 365 483 57.1 10000
0.0601/0.1240 0.0810/0.1600 490 405 562 62.2 12205
The data is approximate an subjected to manufacturing tolerance.
We own the power
197