Electrical and transmission characteristics
1- Conductor resistance at 20O C
Copper conductor diameter
Nominal Minimum Max. Resistance
mm mm mm ohm/Km
0.4 0.385 0.425
0.5 0.485 0.525 149
0.6 0.585 0.625 93
0.9 0.885 0.925 64.5
28
2- Resistance unbalance
Resistance unbalance shall be calculated with the following formula
R ( %) = R max - Rmin X 100
Rmax + Rmin
Resistance unbalance %
Conductor dia Minimum Max.
mm mm mm
2 5
0.4 1.5 5
0.5 1.5 4
0.6 1.2 4
0.9
3- The tensile strength of conductor is max 26 Kg/mm2
and min 20 Kg/mm2
3- Insulation Resistance
The Insulation Resistance at 20 OC is the following
Min. 10000 Mega ohm km for foam skin insulation
Min. 5000 Mega ohm km for solid insulation
4- Mutual Capacitance at 800 HZ
Max average 45 ± 5 nf/km
Max average 50 nf/km
5- Capacitance unbalance Pair
For 160 meter at 800 HZ to earth
Max avarage 500 PF/km
Max individual 2500 PF/km
Max capacitance unbalance
Kind of Reading Avarage Individual
Side to side (within star quad) 70 300
Side to earth 200 450
150
Side to side adjacent pairs -