Page 442 - The City and Guilds Textbook: Plumbing Book 1 for the Level 3 Apprenticeship (9189), Level 2 Technical Certificate (8202) and Level 2 Diploma (6035)
P. 442

The City & Guilds Textbook: Plumbing Book 1

                                            Test your knowledge

                                            1  What is the minimum recommended distribution temperature of hot
                                               water supplied by a storage cylinder?
                                               a  48°C
                                               b  55°C
                                               c  60°C
                                               d  65°C
                                            2  Which Building Regulation relates to the hot water delivery systems in
                                               dwellings?
                                               a  Part F
                                               b  Part G

                                               c  Part P
                                               d  Part L
                                            3  Which one of the following is classed as a localised hot water system?
                                               a  Under-sink single point heater
                                               b  Thermal store
                                               c  Combination boiler
                                               d  Open vented
                                            4  Within an open vented hot water system, which of the following are the
                                               correct connection methods for the open vent pipe off the draw-off pipe?
                                               a  Open vent a minimum of 15 mm diameter connected within 450 mm
                                                  of the draw-off connection from the cylinder
                                               b  Open vent a minimum of 15 mm diameter connected within at least
                                                  450 mm of the draw-off point from the cylinder
                                               c  Open vent a minimum of 22 mm diameter connected within 450 mm
                                                  of the draw-off connection from the cylinder
                                               d  Open vent a minimum of 22 mm diameter connected within at least
                                                  450 mm of the draw-off point from the cylinder

                                            5  The safety devices within an unvented hot water cylinder are designed to
                                               prevent the water from exceeding which of the following temperatures?
                                               a  60°C
                                               b  65°C

                                               c  95°C
                                               d  100°C
                                            6  Where should a secondary return be connected within a hot water storage
                                               cylinder?
                                               a  A quarter of the way down
                                               b  Halfway down
                                               c  Two-thirds of the way from the bottom
                                               d  A quarter of the way up



                430





        9781510416482.indb   430                                                                                    29/03/19   9:02 PM
   437   438   439   440   441   442   443   444   445   446   447