                                                                 An improvement on the one-pipe system, the general layout of the two-pipe
                                                                 heating circuit is still used in modern systems. Heating temperature is
                                           Feed and expansion cistern  controlled by a room thermostat but water temperature is controlled by
                                                                 the boiler thermostat.


                                            22 mm vent pipe
                                                           Room thermostat
                                                          controlling the pump


                         15 mm cold                   Programmer
                           feed pipe


                                                                           22 mm flow and return
                                                        Boiler

                       28 mm gravity
                           primaries







                p  Figure 7.4 Two-pipe semi-gravity system

                One of the biggest problems with older central heating systems was the lack   KEY POINT
                of temperature control on both the hot water and heating circuits, which
                meant that the hot water and the radiators became as hot as the water in the   The two-pipe semi-gravity
                                                                                            system is no longer
                boiler. The C-plan went some way towards addressing this problem with the   installed as it does not
                inclusion of a room thermostat that simply switched off the pump when the   comply with Building
                desired room temperature was reached. The secondary water, however, was still   Regulations Document L.
                uncontrolled and was often too hot.                                         Systems of this type
                                                                                            must be updated to
                                                                                            include full thermostatic
                  Table 7.2 Advantages and disadvantages of the C-plan (two-pipe) system   control over both hot
                                                                                            water temperature and
                 Advantages              Disadvantages                                      room temperatures by
                 All of the heat emitters reach   Uncontrolled heating of the primary circuit leading to   the inclusion of separate
                 the same temperature    overheating of the domestic secondary hot water    controls. The updated
                                         Constant boiler cycling even when the hot water and heating   system is known as the
                                         are up to temperature leads to wastage of fuel energy  C-plan plus.
                 The two-pipe system is much  The system is not Building Regulations Document L
                 quicker at heating up than the  compliant and must be updated to C-plan plus system as a   KEY TERM
                 one-pipe system; this saves   minimum standard
                 on fuel usage                                                              Semi-gravity system: a
                                         The boilers fitted to this type of system are only about 78%
                                         efficient or less                                  central heating system
                                                                                            that has pumped heating
                                         Condensing-type boilers cannot be fitted to this type of
                                         installation because of the gravity circulation needed by the   circulation but gravity hot
                                         hot water storage cylinder                         water circulation.