Page 98 - E24 Electrical Notebook
P. 98
94 - Yellow Power - Product Specifications
Yellow Power Ltd - ‘SENTINEL’ Diesel Range - Product Specification
Genset Model Prime Rating Standby Rating Engine Alternator Dimensions Weight Fuel
@ 400V/220V/50Hz @ 400V/220V/50Hz Manufacturer Manufacturer Length x Width x Height² Consumption
SEN/P10/D (Kgs)
SEN/P14/D (KVA) (KW) (KVA) (KW) MITSUBUSHI STAMFORD (mm) (mm) (mm) 375 (Ltrs/Hr)¹
SEN/P20/D MITSUBUSHI STAMFORD 400 3.1
SEN/P30/D 10 8 10.8 8.6 MITSUBUSHI STAMFORD 1370 520 1360 465 4.3
SEN/P38/D MITSUBUSHI STAMFORD 690 6.2
SEN/P60/D 14 11.2 15.5 12.4 JOHN DEERE STAMFORD 1370 520 1360 1235 8.6
SEN/P80/D JOHN DEERE STAMFORD 1250 10.1
SEN/P100/D 20 16 22 17.6 JOHN DEERE STAMFORD 1630 6650 1200 1350 14.8
SEN/P140/D JOHN DEERE STAMFORD 2200 19.8
SEN/P150/D 30 24 32.5 26 JOHN DEERE STAMFORD 1630 650 1200 1850 23.8
SEN/P200/D JOHN DEERE STAMFORD 1850 31.2
SEN/P250/D 38 30 42 34 JOHN DEERE STAMFORD 2080 670 1370 2140 32.8
SEN/P275/D JOHN DEERE STAMFORD 3125 40
SEN/P325/D 60 48 64 51 STAMFORD 2300 850 1550 3855 54
SEN/P350/D VOLVO STAMFORD 3940 60
SEN/P375/D 80 664 88 70 VOLVO STAMFORD 2300 850 1620 4300 69
SEN/P400/D VOLVO STAMFORD 4440 70
SEN/P450/D 100 80 110 88 VOLVO STAMFORD 2300 850 1570 4460 75
SEN/P500/D VOLVO STAMFORD 4915 83
SEN/P570/D 140 112 150 120 VOLVO STAMFORD 2700 800 1580 5250 92
SEN/P635/D VOLVO STAMFORD 5400 103
150 120 165 132 VOLVO STAMFORD 2700 800 1580 5500 120
VOLVO 129
200 160 220 176 3050 1030 1790
250 200 275 220 3420 1140 2080
275 220 300 240 3420 1140 1920
325 260 360 288 3420 1140 1920
350 280 385 308 3420 1140 2030
375 300 415 332 3420 1140 2030
400 320 440 352 3420 1140 2030
450 360 500 400 3710 1187 2030
500 400 550 440 3710 1187 2270
570 456 660 528 3710 1187 2270
635 508 700 560 3870 1490 2110
Yellow Power Ltd - ‘High Powered’ Diesel Range - Product Specification
Genset Model Prime Rating Standby Rating Engine Alternator Dimensions Weight Fuel
@ 400V/220V/50Hz @ 400V/220V/50Hz Manufacturer Manufacturer Length x Width x Height² Consumption
ML/770/D (Kgs)
ML/900/D (KVA) (KW) (KVA) (KW) MTU LEROY SOMER (mm) (mm) (mm) 5640 (Ltrs/Hr)¹
ML/1000/D MTU LEROY SOMER 6580 158
ML/1130/D 770 616 850 680 MTU LEROY SOMER 3860 1660 1890 6670 185
ML/1250/D MTU LEROY SOMER 7960 205
ML/1550/D 900 720 1000 800 MTU LEROY SOMER 4200 1660 1890 8870 232
ML/1650/D MTU LEROY SOMER 10100 254
ML/1850/D 1000 800 1100 880 MTU LEROY SOMER 4200 1660 1890 11600 315
ML/2100/D MTU LEROY SOMER 12100 335
ML/2250/D 1130 904 1250 1000 MTU LEROY SOMER 5050 2230 2500 14500 372
ML/2600/D MTU LEROY SOMER 14600 422
ML/2850/D 1250 1000 1400 1120 MTU LEROY SOMER 5620 2200 2400 21000 452
ML/3100/D MTU LEROY SOMER 22400 522
1550 1240 1700 1360 MTU LEROY SOMER 5850 2250 2500 24500 573
623
1650 1320 1800 1440 5850 2250 2500
1850 1480 2000 1600 5850 2250 2500
2100 1680 2300 1840 6150 2350 2550
2250 1800 2400 1920 6150 2350 2550
2600 2080 2700 2160 6990 2480 2600
2850 2280 3150 2520 7320 2480 2600
3100 2480 3250 2600 7320 2480 2600
Yellow Power Ltd - Natural Gas Range - Product Specification
Genset Model Continuous Rating Output Efficiency Engine Alternator Dimensions Methane Energy
@ 400V/220V/50Hz Manufacturer Manufacturer Length x Width x Height² No. Input
ML/232/G * KW
ML/390/G (KVA) (KWe) KWe KWth Elec. Total MTU LEROY SOMER (mm) (mm) (mm) ≥80 643
ML/420/G * 232 210 36.1 68.7 MTU LEROY SOMER ≥70 995
ML/772/G * 290 232 390 233 39.2 62.6 MTU LEROY SOMER 3800 1650 2150 ≥80 1064
ML/1166/G * 420 247 39.5 62.7 MTU LEROY SOMER ≥70 1883
ML/1562/G * 488 390 772 434 41 64 MTU LEROY SOMER 3940 1660 2150 ≥70 2822
ML/1948/G * 1166 660 41.3 64.7 MTU LEROY SOMER ≥70 3765
525 420 1562 872 41.5 64.6 MTU LEROY SOMER 3940 1660 2150 ≥70 4685
1948 1078 41.6 64.6
965 772 4000 1700 2400 ≥80 665
≥70 995
1458 1166 4450 1700 2600 ≥80 1064
≥70 1883
1953 1562 5300 1700 2600 ≥70 2822
≥70 3765
2435 1948 5900 1600 2600 ≥70 4685
ML/232/G/HR ** 290 232 232 210 35.4 91.8 MTU LEROY SOMER 3550 1810 2200
ML/390/G/HR ** 488 MTU LEROY SOMER 3850 1870 2250
ML/420/G/HR ** 525 390 390 233 39.2 86.8 MTU LEROY SOMER 3850 1870 2250
ML/772/G/HR ** 965 MTU LEROY SOMER 5500 1800 2400
ML/1166/G/HR * 1458 420 420 247 39.5 86.8 MTU LEROY SOMER 6000 1800 2400
ML/1562/G/HR ** 1953 MTU LEROY SOMER 6800 1800 2600
ML/1948/G/HR ** 2435 772 772 434 41 87.3 MTU LEROY SOMER 7820 1920 2600
1166 1166 660 41.3 87.5
1562 1562 872 41.5 87.1
1948 1948 1078 41.6 87.6
RATING DEFINITIONS TECHNICAL DATA NOTES
Continuous Power (COP) Gas Units only: 1 * Data based on gas generator only, no heat recovery
Continuous Operation at full rated load, 100% load available 2 **Data based on gas generator with full heat recovery
No restriction on operating hours per annum 3 1Fuel consumption based on 100% prime power rating
4 2Dimensions are approximate and for guidance only
Prime Power (PRP) 5 All ratings are based on 40ºC ambient conditions up to 400MASL
Continuous Operation with varying load, typically load factor > 75% 6 All equipment is based on 400V, 50Hz, 1500RPM. Alternative voltages are
Unrestricted operating hours per annum, 10% overload available
available - please seek clarification from Yellow Power Ltd
Standby Power (ESP) 7 Equipment suitable for alternative gas supplies (Bio-Gas, Landfill Gas, etc) are
Standby operation with varying load, typical load factor > 85%
Maximum 500hrs operating per annum, rating at fuel stop, no overload available available - please seek clarification from Yellow Power Ltd
Yellow Power Ltd Tel : 01889 88 22 55
Haywood Mill Fax : 01889 87 80 40
Mill Lane
Great Haywood Email : sales@yellowpower.com
Staffordshire ST18 0RL Website : www.yellowpower.com