P220 Scrubber Series cont.
Specifications Additional features
• Tough glass-filled nylon and stainless steel construction
Dimensions • Internal and External bleed
• 25 mm: 171 x 92 mm H x W • Standard, built-in Schrader-type valve for downstream
• 40 mm: 184 x 92 mm H x W pressure verification
• 50 mm: 241 x 156 mm H x W • Flow control independent of solenoid
• 80 mm: 273 x 156 mm H x W • Self-aligning bonnet to ensure correct installation
• Self-cleaning, stainless steel metering rod
Operating Specifications • Low-flow capability down to 20 Lpm with EZReg
• 316 nuclear-grade stainless-steel filter for maximum
• Flow Range: corrosion resistance
• 25 mm: 20-151 Lpm
• 40 mm: 114-416 Lpm Options Available
• 50 mm: 303-568 Lpm
• 80 mm: 493-1137 Lpm • EZR-30 - EZReg, 30-200 kPa Regulator Module
• Operating Pressure • EZR-100 - EZReg, 30-700 kPa Regulator Module
• 25 mm and 40 mm Models: 70-1500 kPa • 588403: 24 VAC Solenoid Assembly, 50 Hz, Captive Plunger
• 50 mm and 80 mm Models: 140-1500 kPa • DCLS-P - Potted DC Latching Solenoid Assembly (max.
• Minimum pressure differential (between inlet and outlet) for pressure 820 kPa)
TM
pressure regulation: 70 kPa • SGS -12 - Spike Guard Solenoid: 50/60 Hz (24 VAC)
• Body styles:
• Globe/Angle: 25, 40, 50 and 80 mm female threads
• 588403 Solenoid: 24 VAC (50) Standard Warranty
• Inrush: 50 Hz: 0.40 amps • Five years
• Holding: 50 Hz: 0.2 amps
P-220 Scrubber Series Model List
Model Description
P220S-23-54 P220S, 25 mm BSP with ACT™ System
P220S-23-56 P220S, 40 mm BSP with ACT™ System
P220S-23-58 P220S, 50 mm BSP with ACT™ System
P220S-23-50 P220S, 80 mm BSP with ACT™ System
P-220 Scrubber Series Friction Loss Data – kPa
Flow Rate Lpm
Size Configuration
20 35 50 60 75 80 100 120 150 200 250 300 350 400 450 500 550 600 700 800 900 1000 1100
25 mm Globe 32 33 28 24 21 22 32 47 73
18
18
64
42
29
29
Angle
32
22
27
Globe 8 9 12 20 34 52 78 102 131
40 mm
Angle 7 9 11 16 28 43 64 86 111
50 mm Globe 25 33 42 56 64 76
63
43
19
53
26
Angle
35
Globe 15 18 21 28 37 46 56 67
80 mm
Angle 13 16 19 24 32 40 50 61
Flow rates are recommended not to exceed 35 kPa loss.
Note: For optimum performance when designing a system, be sure to calculate total friction loss to ensure sufficient downstream pressure.
For optimum regulation performance, size regulating valves toward the higher flow ranges.
Company policy is one of constant improvement and therefore changes in specifications may
222 be made without notice and without incurring liability. Please refer to www.toro.com.au
Toro Australia Pty Ltd, 53 Howards Road, Beverley, South Australia, 5009.
Phone 1300 130 898, fax (08) 8243 2488. A.B.N. 47 001 310 443