Page 238 - Toro Irrigation Product Catalogue 2020
P. 238

P220 Scrubber Series cont.





         Specifications                                        Additional features
                                                               •  Tough glass-filled nylon and stainless steel construction
         Dimensions                                            •  Internal and External bleed
         •  25 mm: 171 x 92 mm H x W                           •  Standard, built-in Schrader-type valve for downstream
         •  40 mm: 184 x 92 mm  H x W                           pressure verification
         •  50 mm:  241 x 156 mm H x W                         •  Flow control independent of solenoid
         •  80 mm: 273 x 156 mm H x W                          •  Self-aligning bonnet to ensure correct installation
                                                               •  Self-cleaning, stainless steel metering rod
         Operating Specifications                              •  Low-flow capability down to 20 Lpm with EZReg
                                                               •  316 nuclear-grade stainless-steel filter for maximum
         •  Flow Range:                                         corrosion resistance
           •  25 mm: 20-151 Lpm
           •  40 mm: 114-416 Lpm                               Options Available
           •  50 mm: 303-568 Lpm
           •  80 mm: 493-1137 Lpm                              •  EZR-30 - EZReg, 30-200 kPa Regulator Module
         •  Operating Pressure                                 •  EZR-100 - EZReg, 30-700 kPa Regulator Module
           •  25 mm and 40 mm Models: 70-1500 kPa              •  588403: 24 VAC Solenoid Assembly, 50 Hz, Captive Plunger
           •  50 mm and 80 mm Models: 140-1500 kPa             •  DCLS-P - Potted DC Latching Solenoid Assembly (max.
         •  Minimum pressure differential (between inlet and outlet) for   pressure 820 kPa)
                                                                                 TM
           pressure regulation: 70 kPa                         •  SGS -12 - Spike Guard  Solenoid: 50/60 Hz (24 VAC)
         •  Body styles:
           •  Globe/Angle: 25, 40, 50 and 80 mm female threads
         •  588403 Solenoid: 24 VAC (50) Standard              Warranty
           •  Inrush: 50 Hz: 0.40 amps                         •  Five years
           •  Holding: 50 Hz: 0.2 amps

                                                                        P-220 Scrubber Series Model List
                                                               Model         Description
                                                               P220S-23-54   P220S, 25 mm BSP with ACT™ System
                                                               P220S-23-56   P220S, 40 mm BSP with ACT™ System
                                                               P220S-23-58   P220S, 50 mm BSP with ACT™ System
                                                               P220S-23-50   P220S, 80 mm BSP with ACT™ System




                                          P-220 Scrubber Series Friction Loss Data – kPa
                                                                 Flow Rate Lpm
          Size  Configuration
                       20  35  50  60  75  80  100  120  150  200  250  300  350  400  450  500  550  600  700  800  900  1000 1100
         25 mm  Globe  32  33  28  24  21  22  32  47  73
                                           18
                                       18
                                                       64
                                                   42
                                               29
                       29
                Angle
                           32
                                   22
                               27
                Globe                      8   9   12  20  34  52  78  102  131
         40 mm
                Angle                      7   9   11  16  28  43  64  86  111
         50 mm  Globe                                              25  33  42  56  64  76
                                                                                      63
                                                                               43
                                                                   19
                                                                                   53
                                                                       26
                Angle
                                                                           35
                Globe                                                              15  18  21  28  37  46  56  67
         80 mm
                Angle                                                              13  16  19  24  32  40  50  61
        Flow rates are recommended not to exceed 35 kPa loss.
        Note: For optimum performance when designing a system, be sure to calculate total friction loss to ensure sufficient downstream pressure.
        For optimum regulation performance, size regulating valves toward the higher flow ranges.
                                                                  Company policy is one of constant improvement and therefore changes in specifications may
        222                                                       be made without notice and without incurring liability. Please refer to www.toro.com.au
                                                                  Toro Australia Pty Ltd, 53 Howards Road, Beverley, South Australia, 5009.
                                                                  Phone 1300 130 898, fax (08) 8243 2488. A.B.N. 47 001 310 443
   233   234   235   236   237   238   239   240   241   242   243