Page 28 - Arnold CM. ARCH. PORTFOLIO
P. 28

THE MAIN BUILDING;




































                                                                                    An Elevated Louvered Dome Structure, supported by Concrete beam.


                                                                                    It is opened up along the Wind axis by a Lateral hyperbolic structure

                               Ground Floor                                         which creates the "Wind Tunnel" to actively cool the building.






















                                                                                                                                                                                                       Exhibi(on Space on
                                                                                                                                                                                                    Ground/Mezanine Floor






















                           Mezzanine Floor                                                                  First Floor                                                                           The Hanging Restauranton
                                                                                                                                                                                                             First Floor





















                                                                                                                                                                                                    Research & Study Space
                                                                                                                                                                                                           Second Floor






















                               Second Floor                                                                   Roof Plan                                                                                 Conference Room
                                                                                                                                                                                                           Second Floor

                                                                                                                                                               Top Roof Level
                                                                                                                                                               32.580          -The Concrete Beams are
                                                                                                                                                               Core Beam Level
                                                                                                                                                                                 Connected to a
                                                                                                                                                               30.300
                                                                                                                                                               Second Cieling Level Compresion ring (on top

                                                                                                                                                               25.300
                                                                                                                                                                                 of The dome) which

                                                                                                                                                                                 stabilises the forces.



                                                                                                                                                                               -Four Concete column
                                                                                                                                                               Second Floor Level
                                                                                                                                                               15.000
                                                                                                                                                                                 tower high around the

                                                                                                                                                               First Floor Level
                                                                                                                                                               10.000            li4 sha4. They support
                                                                                                                                                                                 the Floor slabs through

                                                                                                                                                                                 lateral beams.


                                                                                                                                                                ±0
                                                                                                                                                               Ground Floor Level
                                                                                                                                                               Ground Level    -The tensile membrane
                                                                                                                                                               -0.600
                                                                                                                                                                                 that covers the wind

                        Sec(on (S-02)                                                                                                                                            tunnel is supported steell

                                                                                                                                                                                 cables







  GSPublisherVersion 0.75.100.100