Page 798 - Hall et al (2015) Principles of Critical Care-McGraw-Hill
P. 798

References     5


                      127. Goularte TA, Manning M, Craven DE. Bacterial colonization     144. Holzapfel  L,  Chastang  C,  Demingeon  G,  Bohe  J,  Piralla  B,
                        in humidifying cascade reservoirs after 24 and 48 hours of con-  Coupry A. A randomized study assessing the systematic search
                        tinuous mechanical ventilation. Infect Control. 1987;8:200-203.  for maxillary sinusitis in nasotracheally mechanically ventilated
                      128. Craven DE, Goularte TA, Make BJ. Contaminated condensate   patients. Influence of nosocomial maxillary sinusitis on the
                        in mechanical ventilator circuits. A risk factor for nosocomial   occurrence of ventilator-associated pneumonia.  Am J Respir
                        pneumonia? Am Rev Respir Dis. 1984;129:625-628.         Crit Care Med. 1999;159:695-701.
                      129. Craven  DE,  Steger  KA,  Barber TW. Preventing  nosocomial     145. Rouby JJ, Laurent P, Gosnach M, et al. Risk factors and clinical
                        pneumonia: state of the art and perspectives for the 1990s.    relevance of nosocomial maxillary sinusitis in the critically ill.
                        Am J Med. 1991;91:44S-53S.                              Am J Respir Crit Care Med. 1994;150:776-783.
                      130. Martin C, Perrin G, Gevaudan MJ, Saux P, Gouin F. Heat and     146. Kollef MH, Von Harz B, Prentice D, et al. Patient transport
                        moisture exchangers and vaporizing humidifiers in the inten-  from intensive care increases the risk of developing ventilator-
                        sive care unit. Chest. 1990;97:144-149.                 associated pneumonia. Chest. 1997;112:765-773.
                      131. Roustan JP, Kienlen J, Aubas P, Aubas S, du Cailar J. Comparison     147. Wunderink RG. Clinical criteria in the diagnosis of ventilator-
                        of  hydrophobic  heat  and  moisture  exchangers  with  heated   associated pneumonia. Chest. 2000;117:191S-194S.
                        humidifier during prolonged mechanical ventilation. Intensive     148. Wunderink RG. Radiologic diagnosis of ventilator-associated
                        Care Med. 1992;18:97-100.                               pneumonia. Chest. 2000;117:188S-190S.
                      132. Dreyfuss D, Djedaini K, Gros I, et al. Mechanical ventilation     149. Wunderink RG, Woldenberg LS, Zeiss J, Day CM, Ciemins J,
                        with heated humidifiers or heat and moisture exchangers:   Lacher DA. The radiologic diagnosis of autopsy-proven ventila-
                        effects  on patient  colonization  and  incidence  of  nosocomial   tor-associated pneumonia. Chest. 1992;101:458-463.
                        pneumonia. Am J Respir Crit Care Med. 1995;151:986-992.    150. Meduri GU, Mauldin GL, Wunderink RG, et al. Causes of fever
                      133. Hurni JM, Feihl F, Lazor R, Leuenberger P, Perret C. Safety of   and pulmonary densities in patients with clinical manifestations
                        combined heat and moisture exchanger filters in long-term   of ventilator-associated pneumonia. Chest. 1994;106:221-235.
                        mechanical ventilation. Chest. 1997;111:686-691.     151. Winer-Muram HT, Steiner RM, Gurney JW, et al. Ventilator-
                      134. Kirton OC, DeHaven B, Morgan J, Morejon O, Civetta J. A pro-  associated pneumonia in patients with adult respiratory distress
                        spective, randomized comparison of an in-line heat moisture   syndrome: CT evaluation. Radiology. 1998;208:193-199.
                        exchange filter and heated wire humidifiers: rates of ventilator-
                        associated early-onset (community-acquired) or late-onset     152. Fagon JY. Diagnosis and treatment of ventilator-associated
                        (hospital-acquired) pneumonia and incidence of endotracheal   pneumonia: fiberoptic bronchoscopy with bronchoalveolar
                        tube occlusion. Chest. 1997;112:1055-1059.              lavage is essential. Semin Respir Crit Care Med. 2006;27:34-44.
                      135. Djedaini K, Billiard M, Mier L, et al. Changing heat and mois-    153. Pugin J, Auckenthaler R, Mili N, Janssens JP, Lew PD, Suter PM.
                        ture exchangers every 48 hours rather than 24 hours does not   Diagnosis of ventilator-associated pneumonia by bacteriologic
                        affect their efficacy and the incidence of nosocomial pneumo-  analysis of bronchoscopic and nonbronchoscopic “blind” bron-
                        nia. Am J Respir Crit Care Med. 1995;152:1562-1569.     choalveolar lavage fluid. Am Rev Respir Dis. 1991;143:1121-1129.
                      136. Conti G, De Blasi RA, Rocco M, et al. Effects of the heat-     154. Schurink CA, Nieuwenhoven CA, Jacobs JA, et al. Clinical pul-
                        moisture exchangers on dynamic hyperinflation of mechanically   monary infection score for ventilator-associated pneumonia:
                        ventilated COPD patients. Intensive Care Med. 1990;16:441-443.  accuracy and inter-observer  variability.  Intensive Care Med.
                      137. Ploysongsang Y, Branson R, Rashkin MC, Hurst JM. Pressure   2004;30:217-224.
                        flow characteristics of commonly used heat-moisture exchang-    155. Luyt CE, Chastre J, Fagon JY. Value of the clinical pulmonary infec-
                        ers. Am Rev Respir Dis. 1988;138:675-678.               tion score for the identification and management of ventilator-
                      138. Dreyfuss D, Djedaini K, Weber P, et al. Prospective study of   associated pneumonia. Intensive Care Med. 2004;30:844-852.
                        nosocomial pneumonia and of patient and circuit colonization     156. Torres A, el-Ebiary M, Padro L, et al. Validation of different
                        during mechanical ventilation with circuit changes every 48   techniques for the diagnosis of ventilator-associated pneu-
                        hours versus no change. Am Rev Respir Dis. 1991;143:738-743.  monia.  Comparison with immediate  postmortem pulmonary
                      139. Kollef MH, Shapiro SD, Fraser VJ, et al. Mechanical ventilation   biopsy. Am J Respir Crit Care Med. 1994;149:324-331.
                        with or without 7-day circuit changes. A randomized controlled     157. Croce MA, Swanson JM, Magnotti LJ, et al. The futility of the
                        trial [see comments]. Ann Intern Med. 1995;123:168-174.  clinical pulmonary infection score in trauma patients. J Trauma.
                      140. Long MN, Wickstrom G, Grimes A, Benton CF, Belcher B, Stamm   2006;60:523-527; discussion 7-8.
                        AM. Prospective, randomized study of ventilator-associated     158. Fabregas N, Ewig S, Torres A, et al. Clinical diagnosis of ventila-
                        pneumonia in patients with one versus three ventilator circuit   tor associated pneumonia revisited: comparative validation using
                        changes per week. Infect Control Hosp Epidemiol. 1996;17:14-19.  immediate post-mortem lung biopsies. Thorax. 1999;54:867-873.
                      141. Guidelines for prevention of nosocomial pneumonia. Centers     159. Fartoukh M, Maitre B, Honore S, Cerf C, Zahar JR, Brun-
                        for Disease Control and Prevention. MMWR Morb Mortal Wkly   Buisson C. Diagnosing pneumonia during mechanical venti-
                        Rep. 1997;46:1-79.                                      lation: the clinical pulmonary infection score revisited.  Am J
                      142. Masterton R, Craven D, Rello J, et al. Hospital-acquired pneu-  Respir Crit Care Med. 2003;168:173-179.
                        monia guidelines in Europe: a review of their status and future     160. Jung B, Embriaco N, Roux F, et al. Microbiogical data, but not
                        development. J Antimicrob Chemother. 2007;60:206-213.   procalcitonin improve the accuracy of the clinical pulmonary
                      143. Rello J, Lode H, Cornaglia G, Masterton R. A European care   infection score. Intensive Care Med. 2010;36:790-798.
                        bundle  for  prevention  of  ventilator-associated  pneumonia.     161. Rosbolt MB, Sterling ES, Fahy BG. The utility of the clinical
                        Intensive Care Med. 2010;36:773-780.                    pulmonary infection score. J Intensive Care Med. 2009;24:26-34.








            Section04-O-ref.indd   5                                                                                   1/21/2015   11:23:24 AM
   793   794   795   796   797   798   799   800   801   802   803