                                           Reference                Purpose                         Variables                                                                  Results                    Comments




                                                                                          Dependent         Independent          Characteristics of Wound
                                                                                                                                         Dressings

                                 1)Mac Nally, C., &        Quantifying the increase  Increase  of skin  -Type of              Allevyn◊ non-adhesive,              No clinically significant effects   The effects
                                 Woodings,S. (2012)        of dose on the skin and      dose  and shift     wound             Allevyn◊ Ag (dry and wet):          at surface for electron beam        measured become
                                 Changes to dose at        the change of dose           of dose at depth    dressing used.   Allevyn◊ Gentle Border &             energies and at depth with          exaggerated when
                                 surface and shifts of     coverage at depth                                -Thickness of     Allevyn◊ Gentle, Mepilex®           photon or electron beam             dressings are wet.
                                 dose distribution at      through different wound                          wound             Border (dry and wet),               energies. For photon beams, the  Assess dressings
                                 depth through dry and  dressings.                                          dressing used     Mepilex® Lite (dry and wet),        presence of a dressing caused       with exudating
                                 wet wound dressings                                                        -Beam Type        Convatec Duoderm® (dry) &           clinically significant effects at   wounds prior to
                                 for photon and                                                             and quality       BSN Fixomull® stretch (dry          the surface.                        treatment.
                                 electron beam                                                              use               and wet)
                                 radiotherapy.
                                 Australian College of
                                 Physical Scientists
                                 and Engineers in
                                 Medicine.




                                 2) Butson, M. J.,         Investigate variations in    Skin dose           Size of           Mepitel® 5cmx5 cm to 40cmx          Increases in skin dose produced  No clinical trials
                                 Cheung, T., Yu, K.        skin dose caused by a        variations          Mepitel®          40 cm                               by Mepitel® range from 14%          reported though
                                 N. P., & Metcalfe, P.     silicon-based burn                               dressing                                              for 5 cm x 5cm field at surface     they began in
                                 (2002). Measurement       dressing used in                                                                                       to 4 % of the maximum for a         2002.
                                 of skin dose              radiotherapy during                                                                                    40 cm x 40cm field at 1 mm
                                 variations produced       treatment                                                                                              depth with a definite variation
                                 by a silicon-based                                                                                                               in delivered dose due to the
                                 protectve dressing in                                                                                                            mesh pattern of the silicon
                                 radiotherapy. Physics                                                                                                            dressing. Effective thickness of
                                 in Medicine and                                                                                                                  the dressing was calculated to
                                 Biology.                                                                                                                         be 0.5 mm water equivalence.