                Temp.correction factor         0.823                          0.825


                Pump up time,min               2.62 min                       1.40 min


                Power taken by comp.kW         44.89 kW                       41.69 kW


                Free Air Delivery in cfm       172.21 cfm                     164.81 cfm



                Volumetric Efficiency          79.08 %                        75.68 %


                Specific   Consumption     in  0.260 kw/cfm                    0.252 kw/cfm
                kW/cfm




               9.2.1  Percentage leakage quantification test

                                       Table 8. Percentage leakage quantification test



                Avg.Load time in Min    NA min


                Avg.UnLoad  time  in  NA  min
                Min


                System      Percentage  NA
                Leakage



                System         Leakage  Due  to  non  availability  of  plant  shutdown,  percentage  leakage
                Quantity in CFM         quantification test not carried out.



                Energy  Loss  due  to  Air  NA
                Leakage