Page 38 - Arebian
P. 38
38
Temp.correction factor 0.823 0.825
Pump up time,min 2.62 min 1.40 min
Power taken by comp.kW 44.89 kW 41.69 kW
Free Air Delivery in cfm 172.21 cfm 164.81 cfm
Volumetric Efficiency 79.08 % 75.68 %
Specific Consumption in 0.260 kw/cfm 0.252 kw/cfm
kW/cfm
9.2.1 Percentage leakage quantification test
Table 8. Percentage leakage quantification test
Avg.Load time in Min NA min
Avg.UnLoad time in NA min
Min
System Percentage NA
Leakage
System Leakage Due to non availability of plant shutdown, percentage leakage
Quantity in CFM quantification test not carried out.
Energy Loss due to Air NA
Leakage