                Sr.no.   Observations and recommendations



                19       Observed two thermic fluid circulation pumps are on for single thermic fluid heater.
                         Information collect from Engg.dept that to maintain proper pressure ,second pump
                         taken on line. One of the reason for above is due to carbonization inside the transfer
                         pipelines.  It  increases  the  pressure  drop  considerably  in  the  system.  and  second
                         reason is that addition of heating equipments in the original process plant area.

                         Periodical  testing  of  thermic  fluid  oil  is  necessary  to  maintain  maximum
                         effectiveness.