EQUIPMENT
     Tuttnauer Autoclave Sterilizers









                  TUTTNAUER AUTOCLAVE STERILIZERS
       Catalog# Description                           Package
         1730   TUTTNAUER 1730  AUTOCLAVE                EA
         EZ10   TUTTNAUER EZ10 AUTOCLAVE EZ10            EA
       EZ11 PLUS TUTTNAUER EZ11 PLUS AUTOCLAVE EZ11 PLUS  EA



      Features:
      • Four Preloaded cycles: unwrapped instruments, wrapped/packs and porous loads, glassware or slow exhaust for liquids or additional drying cycle.
      • Power outage recovery system - unit will automatically complete cycle during a power outage. Certain parameters have to be met.
      • Well thought out door design prevents steam from coming in contact with control panel
      • Exceptionally deep chamber is perfet for longer instruments such as in lipo suction cannulas
      • Chamber is 316L grade electro-polished stainless steel and comes with a ten-year warranty.
      • Optional internal printer documents: date, time, temperature and pressure.
      • 510k clearance for dental hand pieces.
      • Valve for draining is located on the front, allowing for fast and easy draining of water reservoir.
      • International certi cations.
      • 2-year parts and labor warranty





































       • Enhanced closed door active drying system maintains the sterile   • Bacteriological HEPA  lter 0.2 µm air  lter (replaceable).
        eld and ensures complete drying of packs and pouches.  • Contemporary Design with bright blue easy to read LED digital control panel
       • The e cient air pump forces hot air circulation after the sterilization  • All program parameters can be customized and stored
       cycle for faster more e cient closed door drying.    • Double safety locking device keeps the door from opening while the chamber
       • Automatic shut o  commences at the end of the sterilization and dry is pressurized.
       cycles.                                              • A Low water sensor will stop activation of sterilization cycle when there is not
       • Audible and visual cycle interruption alerts for less down time  enough water in the chamber or reservoir.
                                                            • Constant monitoring of temperature and pressure for accurate precise sterilization.