Page 61 - LCS Catalog Final
P. 61
EQUIPMENT
Ultrasound Systems
The DP-50 is engineered to help you get the information you need with an innovative high performance
compact B/W system.
The DP-50’s X-treme engine and high speed processing power provides outstanding image
quality and a complete information management solution.
The insightful design reaches a wide range of clinical applications including abdomen,
urology, OB/GYN, small parts, emergency, orthopedics, endocavity, and interventional medicine.
System Part Number DP-50 Transducers & Needle Guides Part Number
DP-50 Ultrasound System Convex Array Transducers
DP-50 1151E-PA00002 35C50EA Convex Array Transducer:
Standard Con guration: (2.0/3.5/4.5/6.0MHz) PR2A-30-90953
15" LCD monitor Needle guide bracket for 35C50EA (NGB-001) (Stainless
Dual transducer connector Steel) PR1A-30-90212
320G massive hard disc for image storage Needle guide bracket for 35C50EA (NGB-001) (Stainless 115-002020-00
TM
iBeam Spatial Compounding Imaging Steel)
TM
iClear Adaptive Speckle Suppression Imaging 65C15EA Micro-Convex Array Transducer: PR2D-30-90961
TM
iTouch Auto Optimization (5.0/6.5/7.5/8.0MHz)
Phase Shift Harmonic Imaging Needle guide bracket for 65C15EA (NGB-005) (Stainless 0022-30-90461
Trapezoid Imaging, B Steer Imaging Steel)
Imaging modes: B/2B/4B/M/B+M 65EC10EA Endocavity Transducer: (5.0/6.5/7.5/8.5MHz) PR3A-30-90966
TM
iStation Patient Information Management System Needle guide bracket for 65EC10EA (NGB-004)
8-segment TGC PR3A-30-91145
DP-50 Options Part Number (Stainless Steel)
DICOM 3.0 Basic Dicom 110-001217-00 Linear Array Transducers
DICOM 3.0 Worklist 110-001218-00 75L53EA Linear array transducer: (5.0/7.5/8.5/10.0MHz) PL2K-30-91011
IMT Auto Measurement Package 110-001285-00 Needle guide bracket for 75L53EA (NGB-007) (Plastic) 0022-30-90739
0
0
2
Needle guide bracket for 75L53EA (NGB-007) (Stainless Steel)2-30-33013
Miscellaneous Accessories Part Number
Hand carried bag 048-001497-00 75L38EA Linear Array Transducer: (5.0/7.5/8.5/10MHz) PL1A-30-90971
External DVD-R/W (USB, EU power cord) 2108-30-66159 Needle guide bracket for 75L38EA (NGB-002) (Stainless Steel)A-30-90241
1
L
P
UMT-150 mobile trolley 045-000630-00 10L24EA Linear array transducer:
Water-resistant footswitch for DP-50 (USB port, two keys) 0020-30-90810 120-000693-00
Water-resistant footswitch for DP-50 (USB port, three keys)115-005252-00 (8.0/10.0/12.0/14.0MHz)
1
1
0
0
-
5
Rechargeable battery (6600mAh,14.8V) M05-010005-09 Needle-Guided Brackets for 10L24EA (NGB-016) (Stainless Steel)3806-00
Bi-Plane Array Transducers
65EB10EA Electronic bi-plane transducer: (5.0/6.5/7.5/8.5MHz)001147-00
2
-
0
1
Performance Needle-Guided Brackets for 65EB10EA (NGB-004) 120-001451-00
Diagnostic con dence with advanced imaging technologies
• Dynamic Beam Forming Ergonomics
• iBeam™ Spatial Compounding Imaging • Innovative Unit
• iClear™ Speckle Reduction Imaging • Thin Magnesium-alloy body
• (THI) Tissue Harmonic Imaging • 15.6” LED HD monitor with slim design
• (TSI) Tissue Specific Imaging • Built-in battery providing >120 min scanning time
• B Steer, Trapezoid Imaging, Colorization • High capacity SSD hard drive making patient data safer
Exceptional Ergonomics and High Productivity by Design
Designed with the user in mind, the DP-50 makes any location accessible. Customized Special Design Trolley
• A smart new shape for enhanced mobility that is compact and lightweight • Inbuilt quick & easy locking system
• Quick Save One push image transfer to local or directly to USB • iPower: over 3.5 hours scanning with trolley mounted
• iTouch™ Auto Optimization single button image optimization battery pack
• iZoom™: enables accurate viewing of image from distance
• iStation™: clipboard, onboard reporting Multi-Beam Formation
• IMT: auto-measurement of carotid intimae-thickness Maximum 12 times tasking for one transmitted beam,
• 15” high definition LCD, tilt display resulting in excellent time resolution and higher frame
• Backlit control panel rate.
• Li-ion battery, endurance time: >120 min 61
www.Painsuperstore.com Toll Free 877-527-4633 Fax 888-566-0216

