Page 60 - bukuneutron
P. 60

where neutron source-detector gauge is placed
       in the proper shielding container where the in-
       fluence from external neutron is eliminated. The
       trend of count ratio should be recorded and anal-
       ysed regularly. Count statistic with at least around
       five counts are recommended for calculating the
       average standard count to ensure error in the
       count ratio is minimised.

 10. Air Gaps: Air gaps between soil and access tube
       is difficult to eliminate. The gaps itself is not greatly
       affect the neutron count rate but the water can
       flow and filling the gaps. The water in the gap
       can affect the neutron count rate. Other possi-
       bility that can cause high neutron rate is the ex-
       istance of sand around the access tube. Solidify
       clay can be used to fill the air gaps and minimise
       flow of water surrounding the access tube. Oth-
       erwise, the area with high potential of water to
       flow should be avoided.

2.8 Summary

This chapter discuss the principle, applications and some
pros and cons of the neutron back scatterred tech-
nique for moisture measurement in oil and gas indus-
tries, hydrology,agriculture and civil engineering. There
are still some others but not discuss in this chapter.