Page 128 - 3rd issue
P. 128

High & Extra High Voltage Power Cables

Operating Voltage from 38 / 66 KV up to                      Designation Code for High & Extra High
127 / 220 KV Cable Construction                              Voltage Power CablesYou can order
                                                             our product by giving the following
 1. Conductor                                                informations

    Conductor consists of stranded Aluminum or soft          1- cable codes as per the catalogue
    drawn copper that produced by two technologies:          2- if your requirements is out of our
                                                             catalogue product range, you can use the
 a. Circular Compacted                                       following map to identify the code

    Multi layers of stranded wires are assembled              Conductor Material                                          Outer
    together to form a circular compacted conductor                                                                 Sheathing Type
                                                              G Copper + Swelling Powder + S.C Tape
 b. Segmental Conductor (Applied from                         E Aluminum + Swelling Powder + S.C Tape                  P PVC
 C.S.A = 1000 mm2 and above)                                  M Copper Millikan + Swelling Powder + S.C Tape           F PVC / FR
                                                              N Aluminum Millikan + Swelling Powder + S.C Tape         S LSHF
    Five segments of compacted conductor in sector                                                                     H HDPE
    shape of 72o are assembled together with                          C.S.A mm2                                        L LDPE
    separation of non-metallic tapes to reduce the skin                                                                E LLDPE
    effect which reduce the Rac                              25 300                                                    M MDPE
                                                             26 400
 2. Conductor Screen (Bonded to the                          27 500                                                     Armoring
 inner layer of the insulation layer)                        28 630                                                    & Shielding
                                                             29 800
    An extruded layer of cross linkable semi conducting      30 1000                                            B Lead Sheathed
    applied over the conductor to reduce and control         31 1200                                            P Copper Screen + Aluminum foil Shield
    the electric stress beneath the (XLPE) insulation        32 1600                                            R Copper Screen + Lead
    layer                                                    33 2000                                            S Copper Screen + Galavanized Steel Wires
                                                                                                                A Copper Screen + Aluminum Wires
 3. Cross Linked Polyethylene (XLPE)                          Insulation Type                                   C Copper Screen + Aluminum Tapes
 Insulation                                                  X XLPE

    An extruded layer of XLPE of high grad is extruded           Voltage Grade
    in dry cooling & curing continuous vulcanizing line.
                                                             9 26/45 (52) KV
 4. Insulation Screen (Bonded to the                         A 38/66 (72.5) KV
 outer layer of the insulation layer)                        B 64/115 (123) KV
                                                             C 76/132 (145) KV
    An extruded layer of cross linkable semi conducting      D 87/150 (170) KV
    is applied over the insulation layer to insure that the  E 127/220 (245) KV
    electric stress is homogenous around the insulated
    core.                                                    No. of Cores
    Conductor screen, insulation and insulation
    screen are applied in one process (triple extrusion      01 1
    process) to insure that all extruded layers are
    bonded together.

  5. Metallic Screen / Sheath

    One or multi layers of metallic screen / sheath
    such as copper wires, lead, aluminum, etc.shall
    be applied as a return path of earth fault current.
    Metallic sheaths may be used for water blocking
    protection and mechanical protection.

 6. Water blocking:

    Upon request, swelling powder should be applied
    between the conductor strands then Followed by
    swelling semi conductive water blocking tape over
    the complete conductor

 7. Overall Jacket (Outer Sheath)

    An extruded layer of PVC, PE (HDPE, LDPE, and
    MDPE) shall be applied over the metallic
    layers for protection against chemical reaction &
    mechanical protection.Extruded semi conductive
    layer or graphite coating shall be applied over the
    outer sheath for D.C testing purpose
   123   124   125   126   127   128   129   130   131   132   133