MESC

                                                    Specialized Cables
                                  0.6/1 KV  XLPE /PVC  SCREENED CABLES
                                                    IEC60502-1


                  CONSTRUCTION
                   Conductor                 Annealed plain copper conductors stranded to class 2 of IEC-60228.
                  Insulation                 Solid extruded XLPE  as per IEC-60502-1.

                                             2 Core             :  Red,Black
                  Color Code( based on
                  IEC60227-1 & SEC          3 Core              :  Red,Yellow,Blue
                  specification)            4 Core              :  Red,Yellow,Blue & Black
                                            5 Core & above      :  Black cores with Number printing.
                                             Required numbers of insulated conductors assembled with non -hygroscopic
                  Cabling/Assembly
                                            fillers  if necessary  .For cables with 5 cores and above   the assembly is
                                            wrapped with a polyester binder tape.

                                             Extruded PVC compatible with the operating temperature of the conductor.
                  Inner covering

                                             The screen shall consist of copper tape (75μm) applied helically over
                  Screening
                                            the inner covering for 100% coverage and  with a suitable overlap.
                                             Extruded black PVC type ST2 to IEC60502-1.  Flame retardant according to
                  Outer Sheath              IEC 60332-3 Cat. A and Cat C.

                                             CU/XLPE/PVC  SHIELDED   4CX1.5   MM2   600/1000 V   MESC   YEAR
                  Printing on the Sheath(
                  example)                  IEC60502-1  METER MARKING

                  Technical Data

                                                          IEC60332-3 CATC & CAT A
                  Flame retardance
                                                           17% ( IEC 60754-1)
                  Halogen acid gas( outer sheath)
                                                            30 (ASTM D2863)
                  Limiting Oxygen index( outer
                  sheath)
                                                          Passes after 720 hrs ( UL 1581)
                  UV /Sunlight resistance( outer
                  sheath)
                                                          Passes ( ICEA S-82-552)
                  Oil  resistance( outer sheath)
                                                          - 5°C to 50°C (During installation)
                  Temperature Range
                                                          - 20°C to 90°C (During Operation)
                  Voltage Rating                          600/1000 Volts
                                                          Acording to IEC60228.
                  Conductor Resistance
                  Voltage Test                            3500 V r.m.s. for 5 minutes