        Sample signage directing occupants to a
        shelter area within a building.



           Chapter 3 presents an overview of the
        various test protocols employed to assess a   WE CAN
        building envelope’s ability to withstand the
        impact of a wind-borne missile. As a pre-
        cursor to developing this guide, missile im-
        pact tests, using standard steel construction   HELP YOU
        methods and materials, were performed.

        The  ndings from this test program are
        summarized in this chapter, as are previous
        building envelope system tests.          HELP YOUR
           Chapter 4 addresses the importance
        of providing an appropriate load path be-
        tween all building structural elements. The
        most important load paths indicated by
        damage observations are the roof-to-wall   CUSTOMERS.
        connections, the wall-to-foundation con-
        nections and the connections between the
        exterior walls at the corners.  In addition to
        the exterior walls, shear walls in the interi-
        or of the building may reduce the tendency
        for the building to rack and or overturn.
        Adequate shear wall design requires proper   QuickFrames bolt-on, pre-engineered, adjustable RTU frames help teams:
        anchorage at the ends of the shear walls   INCREASE PRODUCTIVITY  |  SOLVE COORDINATION & TIME ISSUES  |  PERFORM BETTER
        and sometimes at the ends of shear wall
        segments. Forces and connection details
        must be properly speci ed and shown on

        the contract documents. In addition, typi-                                quickframes.us       480-464-1500
        cal connection details are illustrated.

                                                                                           Modern Steel Construction | 19