Function and principle of FRL unit





 1. Pneumatic components usually
 consist of internal moving part,   1. This unit combines filter,
 thus adding controlled amount of       regulator and lubricator
 oil lubricant helps to ensure proper   as shown in the Figure X.
 lubrication of the components.         In this unit, filter is the
                                        first component followed
 2. Basically, lubricants are used to   by regulator and
 a. To reduce the wear of the           lubricator.
 moving parts in components,
 b. Reduce frictional losses        2. The arrangement of
 c. Protect components and   Filter-regulator-  these components are in
 equipment from corrosion.  lubricant Unit (FRL)  such a way to prevent 1
                                        foreign matter from
 3. Lubricator is added in the form of   causing a malfunction of
 fine mist and it is placed near the    the regulator. Usually,
 equipment to be lubricated.            lubricator is placed last to
 Lubricator should never be used   Air Lubricator  avoid oil mist or droplets
 on - oil-less compressors.             from deposited in turns or
                                        valves in the system.