Page 88 - Pneumatic ebook (2)_draft 13 sept 2021
P. 88

Shuttle Valve (OR Valve)





 1. Shuttle valve is a three-ported valve which has two inlets and one outlet. When compressed air enters port 12,
 the poppet will be pushed to port 14 and it is blocked, thus compressed air flows from port 12 to port 2.


 2. This valve is also called as OR valve because port 2 able to produce output, if the compressed air is applied
 to either port 12 or 14.

 3. A shuttle valve may be used, when the cylinder or valve is to be actuated from two points, which may be
 remote from one another.
                        Truth table for OR valve

 Shuttle valve      Input 12    Input 14    Output 2

                        0           0            0
 2
                        1           0            1

                        0           1            1
 12  14
                        1           1            1
 Cross sectional view of shuttle valve
 Symbol of shuttle valve                    Click here to watch working
                                               principle of OR valve





 INTRODUCTION TO PNEUMATIC SYSTEM                                  39