Page 45 - Arebian
P. 45
45
Rated Kw 282.60 Kw 282.60 Kw
No.of compressors 2 2
3 Observations
System 1 –Comp. no.1 Standby mode Standby mode
System 2 –Comp. no.1 Is on load Is on load
Dry bulb temp of 26 °C 26 °C
Ambient,°C
Wet bulb temp of 20 °C 20 °C
Ambient,°C
Oil level (observed through Sufficient for two Sufficient for two
sight glass) compressor units observed compressor units observed
from crankcase sight glass. from crankcase sight glass.
Sr.no Description Observations
Measurements starts at ,hr 10:30 am to 6:00 pm 10:30 am to 6:00 pm
Observed load in kW 112.8 Kw 85.8 kW
Percentage compressor loading % 59 % 43 %
Suction pressure, psig 51.2 psig 51.9 psig
Oil pressure, psig 63 psig 63 psig
Discharge pressure, psig 228 psig 195 psig
Evaporator Chilled water Inlet 13°C 13°C
temp,°C
Evaporator Chilled water Outlet 11.8 °C 11.6 °C
temp,°C
Average Delta T across evaporator,°C 1.2 °c 1.4°c
Evaporator inlet chilled water 4.2 Kg/cm2(g) 4.4 Kg/cm2(g)
pressure,Kg/cm2(g)
Evaporator Outlet chilled water 2.8 Kg/cm2(g) 3.0 Kg/cm2(g)
pressure,Kg/cm2(g)