Page 21 - PPE GUIDELINE
P. 21

Guidelines on the Use of PPE Against Chemical Hazards


                       Respirator Selection Flow Chart

                       The following flow chart simplifies the steps in respirator selection.

                       Figure 1: Respirator Selection Flow Chart

                                                                         No
                                                                  Is
                                                             concentration    Yes
                                                              higher than            Use half mask
                             Identify                            PEL?                respirator with
                          Contaminants                                              appropriate filter.

                                                                    Is   No
                            Determine                         concentration    Yes
                          Concentration                      10 times higher           Use full face
                                                                than PEL?             respirator with

                              Is                                     No
                         concentration      Yes                   Is the      Yes       Use full face
                        still unknown?                        concentration            supplied air or
                                                            higher than 100X          PAPR respirator
                                         Do not use air           PEL?                  with hood or
                                           purifying                                    helmet and
                                 No     respirators. Use                             appropriate filter.
                                            SCBA.                    No

                                                                 Is the
                                                       Yes   concentration
                         Does potential   Yes                 higher than
                           for oxygen                         1000X PEL?
                           deficiency
                                                                       No              No respirator
                                                                                          needed.
                                   No              Yes         Does the               Recommended
                                                             concentration
                                                             exceed IDLH?                 only for
                                                                                       concentration
                                                                                        higher than
                                                                                         0.5X PEL









               Department of Occupational Safety & Health, Ministry of Human Resources, Malaysia ™October 2005   21