Page 78 - belden
P. 78

I N DUS T R I A L  A U T O M A TI O N  & P R O C E S S C O NTRO L C A B L E S                      78

        UL Instrumentation Cable
        300V Power-Limited Tray Cables


        12 AWG Pairs
                                           •  UL PLTC, ITC                    • NEC: CL3R
                                           • Sunlight Res                     • CEC: CMG FT4
                                           • Oil Res                          • IEEE 1202/383
                                                                              • ICEA T-29-520

                                        Pull Tension   Bend Radius (Min)    OD (Nom)          Jacket Thickness
           Part No.   Pairs    Color Code  (Max)
                                           Lbs      Inch       mm        Inch      mm        Inch      mm
        12 AWG • Unshielded
         Stranded (65 x 30) TC Conductors • PVC Insulation • PVC Jacket
            9412       1         E2        197      4.25      107.95     .370      9.40      .042      1.07
        12 AWG • Beldfoil  Shielding
                   ®
         Stranded (65 x 30) TC Conductors • PVC Insulation • PVC Jacket
            9312       1         E2       225       4.25      107.95     .373      9.47      .042      1.07


        12 AWG Triads
                                           •  UL PLTC, ITC                    • NEC: CL3R
                                           • Sunlight Res                     • CEC: CMG FT4
                                           • Oil Res                          • IEEE 1202/383
                                                                              • ICEA T-29-520

                                        Pull Tension   Bend Radius (Min)    OD (Nom)          Jacket Thickness
           Part No.   Triads   Color Code  (Max)
                                           Lbs      Inch       mm        Inch      mm        Inch      mm

        12 AWG • Unshielded
         Stranded (7 x 20) BC Conductors • PVC Insulation • PVC Jacket
            3102A      1         E1        315      3.50      88.90      .432     11.00      0.53      1.35



























                 To Specify Conductor, Insulation and Jacket Options:  Bare  Tinned  Insulation/Jacket  Bare  Tinned  Insulation/Jacket
                 1234              A            E         A      B       PVC/PVC     Q      R       XLP/CPE
                               Add or Modify for          C      D       XLP/PVC     S      T     XLP/Haloarrest ®
                Start with
               Base Part No.  Conductor, Insulation,    Add for Exposed
         (1000 and 3000 Series Cables Only)  and Jacket.    Run Rating
                               See table at right.
        BC = Bare Copper • TC = Tinned Copper • CPE = Chlorinated Polyethylene • PVC = Polyvinyl Chloride • XLP = Cross-Linked Poly

                            Fo r  m o r e  i n fo r m at i o n,  c o n t a c t   Be ld e n  Te ch n i ca l  S u ppo r t :   1- 8 0 0 - B E L D E N -1  •  www. b e l d e n . c o m
   73   74   75   76   77   78   79   80   81   82   83