Page 88 - E24 Electrical Notebook
P. 88
84 - Static UPS & Transfer Systems
SOCOMEC For High Quality Power Supply
Our UPS systems, static transfer systems and AC/DC converters (inverters and rectifiers, respectively) comprise the most complete range in the world
and cover a very wide range of applications for every sector of activity.
For further information and technical data sheets, please contact our office on 01285 86 33 00 or email info.uk@socomec.com
IT & Networking / Server Rooms / IT Infrastructure / Data Centres
kVA 0.5 1 2 3 5 10 20 60 100 150 200 300 600 1000kVA
Desk Top / Tower UPS NETYS PI 600-800VA
1+1 desktop
NETYS PL 600-2000VA
1/1 Tower
NETYS PR 1-2kVA
ITYS 1/1 Tower
1-10kVA
1/1 Tower
Convertible 19” NETYS PR 1-1.5kVA
Rack & Rack / Tower UPS 1/1 19” Rack
NETYS PR 1.7-3.3kVA
NETYS RT 1/1
Convertible
Rack/Tower
1.1-11kVA
1/1
Convertible
Rack/Tower
Single Unit & 1+1 MASTERYS BC 8-120kVA
Configuration UPS DELPHYS BC 3/1 & 3/3
10-120kVA/kWA 160-300kVA
3/1 & 3/3 up to 3/3
720 kW
Single Parallel UPS Systems MASTERYS GP
DELPHYS GP 160-800kVA/kWA
DELPHYS MX 3/3 tp to 4 MVA
transformerless
250-900kVA/kW
3/3 transformer based
up to 5.4 MVA
Modular & Scalable UPS MODULYS 1.5-24kVA
Systems 1/1 & 3/1
MODULYS GP 25-600kVA/kW
3/3
fully modular
solution
Non-IT Applications - Industrial & Manufacturing Processes / Transport Infrastructure / Medical Equipment / Emergency Systems
kVA 0.5 1 2 3 5 10 20 60 100 150 200 300 600 1000kVA
Industrial Rugged UPS for MASTERYS IP+ 10-60kVA
Harsh Environments 3/1
MASTERYS IP+ 10-80kVA
3/3
Transformer Based UPS DELPHYS MP 80-200kVA
Elite 3/3 up to 1.2 MVA
DELPHYS MX 250-900kVA
3/3 up to 5.4 MVA
Industrial Modular DC Power SHARYS IP 24/48/108/120v
1.5-200A
Rectifiers up to
200A
Centralised Power Supply for Emergency 3-6kVA
Emergency Systems CPSS 1/1
MODULYS
Emergency 10-20kVA
CPSS 3/1
MASTERYS
Emergency 10-80kVA
CPSS 3/3
MASTERYS
Emergency 80-500kVA
CPSS DELPHYS 3/3
Solutions for Specific NETYS RT-M 1.1-3kVA
Environments ITYS ES 1/1 for marine
PHASYS applications
DELPHYS GP-S
1.1-3kVA
1/1 for electrical
substations
1.5-18kVA
Modular invertor
for telecom
invertors
160-500kVA
3/3 seismic
applications
Scalable UPS for IT & Networking / Server Rooms / Data Centres
DELPHYS XTEND Number of Xbays 4 4 2 5 4 5 2 6 5 6
single cable in / single cable Number of Xmodules (200 kW) 23 400 3 800 1000 400 34 1000 12000
out with distributed or 200 600 600 200 600 800
common bypass 400 800 400 600 800 1000
Power kW N 400 600 800
configuration 200 400 600
N+1
Power kW redundant
configuration
SOCOMEC U.K. Limited Tel : 01285 863300
Units 7A-9A Lakeside Business Park Fax : 01285 862304
Broadway Lane South Cerney
Cirencester Email : info.uk@socomec.com
GL7 5XL Website : www.socomec.co.uk