Page 36 - Dometic RM Series Refrigerators Service Manual
P. 36

36







                 REPLACEMENT OF
                ELEMENT OF THE THERMOELECTRIC
                 FLAME FAILURE SAFETY






                                                                                    Fig. 59

                       replace the thermo-element of the thermoelectric flame failure safety
                        (see  fig.  59).
                 1.           plug A f      the valve housing B .

                2.   Loosen the position nut C and lock nut D .

                     Screw off nut C, remove spacer       and nut D. Release the thcrmo-element E from
                     burner housing F.
                4.   Bend carefully the new thermo-element to the same shape as the old one. Screw
                     nut D into the new element,
                     Put the feeler through the hole in the burner housing F, refit the spacer            and
                     screw the position nut C tight against the shoulder on the feeler, raking sure
                     the nut D is free during this operation,

                 6.  Tighten the lock nut D against the burner housing with a small wrench, if
                     necessary holding nut C vith another wrench, Make sure the feeler is located
                     as  in  figure.

                     Check that no burrs are inside valve housing B which             cause leaks,
                     Screw plug A onto the valve housing B , taking care not to damage the threaded
                     hole in the             cap of the housing, Plug A must be properly tightened to
                     the valve housing to ensure contact betveen the thermo-element and the
                     coil vithin the housing,
                              OF     SAFETY VALVE

                If the safety valve magnet is defective, it cannot be repaired but                be replaced,

                When the safety valve magnet needs replacement         proceed  as follows   (see  fig,

                     Unscrew the connection plug (A) on the thermocouple from the housing nut

                2.   Unscrew the housing nut (B) and remove the defective safety valve                  (C)
                     from the housing

                3.   Fit a new magnet valve and ensure
                     that it is properly inserted in
                     the housing (D).

                4.   Fit the housing nut        and the
                     connection plug (A) and check that
                     a good contact between the contact
                     plug (E) on the thermocouple and
                     the contact (F) on the safety
                     valve magnet is obtained.