Page 524 - Cardiac Nursing
P. 524
009
0-5
8 A
8:2
10.
0
9/0
10.
qxd
M
00
00
ara
Apt
e 5
P
p46
g
P
K34
LWBK340-c21_21_p460-510.qxd 09/09/2009 08:28 AM Page 500 Aptara
K34
21_
0-c
9/2
LWB K34 0-c 21_ p46 0-5 10. qxd 0 9/0 9/2 009 0 0 8:2 8 A M P a a g e 5 00 Apt ara
L L LWB
500 P A R T III / Assessment of Heart Disease
42. O’Grady, N. P., Alexander, M., Dellinger, E. P., et al. (2002). Guidelines 65. Scheer, B., Perel, A., & Pfeiffer, U. J. (2002). Clinical review: Complica-
for the prevention of intravascular catheter-related infections. Centers for tions and risk factors of peripheral arterial catheters used for haemody-
Disease Control and Prevention. Morbidity and Mortality Weekly Report. namic monitoring in anaesthesia and intensive care medicine. Critical
6
6
Recommendations and Reports, 51, 1–29. Care, 6, 199–204.
43. Pratt, R. J., Pellowe, C. M., Wilson, J. A., et al. (2007). epic2: National 66. Barone, J. E., & Madlinger, R. V. (2006). Should an Allen test be per-
evidence-based guidelines for preventing healthcare-associated infections formed before radial artery cannulation? Journal of Trauma, 61, 468–470.
in NHS hospitals in England. Journal of Hospital Infections, 65(Suppl. 1), 67. Jarvis, M. A., Jarvis, C. L., Jones, P. R., et al. (2000). Reliability of Allen’s
S1–S64. test in selection of patients for radial artery harvest. Annals of Thoracic
44. Pronovost, P., Needham, D., Berenholtz, S., et al. (2006). An interven- Surgery, 70, 1362–1365.
tion to decrease catheter-related bloodstream infections in the ICU. New 68. Wallach, S. G. (2004). Cannulation injury of the radial artery: Diagnosis
England Journal of Medicine, 355, 2725–2732. and treatment algorithm. American Journal of Critical Care, 13, 315–319.
45. Berenholtz, S. M., Pronovost, P. J., Lipsett, P. A., et al. (2004). Eliminat- 69. Martin, C., Saux, P., Papazian, L., et al. (2001). Long-term arterial can-
ing catheter-related bloodstream infections in the intensive care unit. nulation in ICU patients using the radial artery or dorsalis pedis artery.
Critical Care Medicine, 32, 2014–2020. Chest, 119, 901–906.
46. Warren, D. K., Zack, J. E., Mayfield, J. L., et al. (2004). The effect of an 70. Parry, T., Hirsch, N., & Fauvel, N. (1995). Comparison of direct pressure
education program on the incidence of central venous catheter-associated measurement at the radial and dorsalis pedis arteries during surgery in the
bloodstream infection in a medical ICU. Chest, 126, 1612–1618. horizontal and reverse Trendelenburg positions. Anaesthesia, 50, 553–555.
6
6
47. Safdar, N., & Abad, C. (2008). Educational interventions for prevention 71. Lipsitz, E. C. (2004). Cannulation injuries of the radial artery. American
of healthcare-associated infection: A systematic review. Critical Care Journal of Critical Care, 13, 314, 319.
Medicine, 36, 933–940. 72. AACN. (1993). Evaluation of the effects of heparinized and nonhep-
6
6
48. Mermel, L. A. (2008). Arterial catheters are not risk-free spigots. Criti- arinized flush solutions on the patency of arterial pressure monitoring lines:
cal Care Medicine, 36, 620–622. The AACN Thunder Project. American Journal of Critical Care, 2, 3–15.
6
6
49. Traore, O., Liotier, J., & Souweine, B. (2005). Prospective study of arte- 73. Randolph, A. G., Cook, D. J., Gonzales, C. A., et al. (1998). Benefit of
rial and central venous catheter colonization and of arterial- and central heparin in peripheral venous and arterial catheters: Systematic review and
venous catheter-related bacteremia in intensive care units. Critical Care meta-analysis of randomised controlled trials. BMJ, 316, 969–975.
6
6
Medicine, 33, 1276–1280. 74. Zevola, D. R., Dioso, J., & Moggio, R. (1997). Comparison of heparinized
50. Rijnders, B. J. (2005). Catheter-related infection can be prevented ... if and nonheparinized solutions for maintaining patency of arterial and pul-
6
we take the arterial line seriously too! Critical Care Medicine, 33, monary artery catheters. American Journal of Critical Care, 6, 52–55.
6
1437–1439. 75. Hall, K. F., Bennetts, T. M., Whitta, R. K., et al. (2006). Effect of he-
51. Gardner, R. (1981). Direct blood pressure measurement. Dynamic re- parin in arterial line flushing solutions on platelet count: A randomised
sponse requirements. Anesthesiology, 54, 227–236. double-blind study. Critical Care and Resuscitation, 8, 294–296.
4
4
52. Promonet C., Anglade D., Menaouar A., et al. (2000). Time-dependent 76. Whitta, R. K., Hall, K. F., Bennetts, T. M., et al. (2006). Comparison of
pressure distortion in a catheter-transducer system: Correction by fast normal or heparinised saline flushing on function of arterial lines. Criti-
flush. Anesthesiology, 92, 208–218. cal Care Resuscitation, 8, 205–208.
53. Gore, S., Middleton, R., & Bridges, E. (1995). Analysis of an algorithm 77. Bradley, C., & Munro, P. (2000). The effect of using a heparin-free flush
to guide decision making regarding direct and oscillometric blood pres- system for central venous and pulmonary artery catheters on a general
4
sure measurement. American Journal of Respiratory and Critical Care medical and surgical intensive care unit. Critical Care, 4, P35.
4
Medicine, 151, A331. 78. Kaye, J., Heald, G. R., Morton, J., et al. (2001). Patency of radial arte-
54. Woda, R. P., Dzwonczyk, R., Buyama, C., et al. (1999). On the dynamic rial catheters. American Journal of Critical Care, 10, 104–111.
performance of the Abbott Safeset™ blood-conserving arterial line sys- 79. O’Rourke, M. F., & Mancia, G. (1999). Arterial stiffness. Journal of
7
tem. Journal of Clinical Monitoring and Computing, 15, 215–221. Hypertension, 17, 1–4.
7
55. Bridges, E. J., Schmelz, J., & Kelley, P. W. (2008). Military nursing re- 80. Rowell, L., Brengelmann, G., Blackmon, J., et al. (1968). Disparities be-
search: Translation to disaster response and day-to-day critical care nurs- tween aortic and peripheral pulse pressures induced by upright exercise
7
7
ing. Critical Care Nursing Clinics of North America, 20, 121–131. and vasomotor changes in man. Circulation, 37, 954–964.
56. Rickard, C. M., Couchman, B. A., Schmidt, S. J., et al. (2003). A dis- 81. O’Rourke, M. (1993). Wave travel and reflection in the arterial system.
card volume of twice the deadspace ensures clinically accurate arterial In M. O’Rourke, M. Safar, & V. Dzau (Eds.), Arterial vasodilation (pp.
blood gases and electrolytes and prevents unnecessary blood loss. Criti- 10–22). Philadelphia: Lea & Febiger.
cal Care Medicine, 31, 1654–1658. 82. O’Rourke, M. F., & Hashimoto, J. (2007). Mechanical factors in arterial
57. Laxson, C. J., & Titler, M. G. (1994). Drawing coagulation studies from aging: A clinical perspective. Journal of the American College of Cardiol-
arterial lines: An integrative literature review. American Journal of Criti- ogy, 50, 1–13.
cal Care, 3, 16–22. 83. Nichols, W. W., Denardo, S. J., Wilkinson, I. B., et al. (2008). Effects of arte-
58. Heap, M. J., Ridley, S. A., Hodson, K., et al. (1997). Are coagulation rial stiffness, pulse wave velocity, and wave reflections on the central aortic pres-
studies on blood sampled from arterial lines valid? Anaesthesia, 52, sure waveform. Journal of Clinical Hypertension (Greenwich), 10, 295–303.
0
0
640–645. 84. Kelly, R., Gibbs, H., O’Rourke, M., et al. (1990). Nitroglycerin has more
59. Hoste, E. A., Roels, N. R., Decruyenaere, J. M., et al. (2002). Significant favourable effects on left ventricular afterload than apparent from measure-
increase of activated partial thromboplastin time by heparinization of the ment of pressure in a peripheral artery. European Heart Journal, 11, 138–144.
radial artery catheter flush solution with a closed arterial catheter system. 85. Westerbacka, J., Tamminen, M., Cockcroft, J., et al. (2004). Compari-
Critical Care Medicine, 30, 1030–1034. son of in vivo effects of nitroglycerin and insulin on the aortic pressure
4
4
60. Carlson, K., Snyder, M., LeClair, H., et al. (1990). Obtaining reliable waveform. European Journal of Clinical Investigations, 34, 1–8.
sodium and glucose determinations from pulmonary artery catheters. 86. Mignini, M. A., Piacentini, E., & Dubin, A. (2006). Peripheral arterial
Heart & Lung, 19, 613–619. blood pressure monitoring adequately tracks central arterial blood pressure
61. Odum, L., & Drenck, N. (2002). Blood sampling for biochemical analy- in critically ill patients: An observational study. Critical Care, 10, R43.
sis from central venous catheters: Minimizing the volume of discarded 87. Pytte, M., Dybwik, K., Sexton, J., et al. (2006). Oscillometric brachial
blood. Clinical Chemistry and Laboratory Medicine, 40, 152–155. mean artery pressures are higher than intra-radial mean artery pressures
62. McNulty, S., Maguire, D., & Thomas, R. (1998). Effect of heparin- in intensive care unit patients receiving norepinephrine. Acta Anaesthesi-
bonded pulmonary artery catheters on activated coagulation time. Jour- ologica Scandinavica, 50, 718–721.
nal of Cardiothoracic and Vascular Anesthesia, 12, 533–535. 88. Umana, E., Ahmed, W., Fraley, M. A., et al. (2006). Comparison of os-
63. Leyvi, G., Zhuravlev, I., Inyang, A., et al. (2004). Arterial versus venous cillometric and intraarterial systolic and diastolic blood pressures in lean,
7
7
sampling for activated coagulation time measurements during cardiac overweight, and obese patients. Angiology, 57, 41–45.
surgery: A comparative study. Journal of Cardiothoracic Vascular Anesthe- 89. Manios, E., Vemmos, K., Tsivgoulis, G., et al. (2007). Comparison of
sia, 18, 573–580. noninvasive oscillometric and intra-arterial blood pressure measurements
64. Haering, J., Maslow, A., Parker, R., et al. (2000). The effect of heparin- in hyperacute stroke. Blood Pressure Monitoring, 12, 149–156.
coated pulmonary artery catheters on activated coagulation time in car- 90. Smulyan, H., Sheehe, P. R., & Safar, M. E. (2008). A preliminary evalu-
diac surgical patients. Journal of Cardiothoracic and Vascular Anesthesia, ation of the mean arterial pressure as measured by cuff oscillometry.
4
4
14, 260–263. American Journal of Hypertension, 21, 166–171.

