Page 154 - PONPE Catalogs 2022
P. 154

PROTRONICS CO.,LTD.
        145                          Measuring Instruments Store
                                     Line: @ponpe / Facebook: »¹à» / Tel: 02-5316293,5-6 / Website: www.ponpe.com


          FG100                                                   AR8500

























                                                  Specifications
          Specifications                          Color: Black + gray
         Meas. ranges: Propane: 500 to 6500 ppm;  Display screen: Large screen lcd
                   Natural gas: 1000 to 6500 ppm  Gas type:  Ammonia (NH3), gas detectir
         Power: 2 x 'AAA' 1.5V batteries;        Measuring range: 0 ~ 100PPM
         Operating conditions: 10 to 50°C        Resolution: 0.1PPM
                         <95% RH non-condensing  Basic Error: 0.5PPM
         Storage conditions: 5 to 55°C           Response time: Less than 120 seconds
                       <5% RH (non condensing)   Restore: Less than 120 seconds
         Dimensions: 7.1" Length; 0.8": diameter"   Repeatability: Less than ± 1%
         Weight: 1.6 oz (46g)                    Working temperature: - 20 ~ 50°C
                                                 Working Humidity: <95% RH (Non-gel)
                                                 Temperature: 0 ~ 40 °C


          BX616                                                   G02-CO-B3























                                                  Specifications
                                                 Power supply: 9~24VAC/VDC, 230VAC
                                                 Consumption: 2.8 W
         Specifications
         Range: CO: 0-1000 ppm                   Signal update: 1s
              O2: 0-30% VOL                      Warm up time: 36 hours (first time), 10 minutes (normal operation)
              H2S: 0-100 ppm                     CO measuring range: 0~500ppm or customized range
              LEL: 0-100%                        CO setting resolution: 0.1ppm
         Alarm Points: CO: 35 and 200 ppm instant,  Humidity measurement range: 99 %RH
                   TWA: 35 ppm STEL: 200 ppm     Buzzer alarm: Alarm starts when CO measurement reach up the presets
         H2S: 10 and 15 ppm instant, TWA: 10 ppm STEL: 15 ppm  LCD backlit: Greenoptimal air quality
         O2: 19.5% by Vol decreasing 23.5% by Vol increasing   Yellow1st CO alarm level
         LEL: 20 and 50% LEL                              Red-2nd CO alarm level
         Humidity Range: 5 to 95% RH, non-condensing  Dimensions: 130mm(L)×85mm(W)×36.5mm(H)


              38/40-41 ËÁÙ‹·Õè 3 ¶¹¹ÅÓÅÙ¡¡Ò µÓºÅ¤Ù¤µ
         ÍÓàÀÍÅÓÅÙ¡¡Ò ¨Ñ§ËÇÑ´»·ØÁ¸Ò¹Õ 12130                                                           เครื่องวัดแก�ส
   149   150   151   152   153   154   155   156   157   158   159