Page 6 - A4 Post tensioning bar 1030
P. 6

Macalloy Post Tensioning System


                Stress corrosion testing has also   Welding                       thread, when cast into concrete,
                been conducted in accordance     Macalloy 1030 and Macalloy       or grouted into a preformed hole,
                with pr EN 10138-4: 2005-2009 and   S1030 must not be welded,     complies with requirements for a
                satisfies the requirements in full.  subjected to high local heating   Class 2 deformed bar. This is as per
                                                 or splashed with weld metal.     8110-1:1997 Section 3.12.8.
                Under    normal   circumstances,
                Macalloy 1030 is not susceptible                                  Short, fully threaded bars can
                to stress corrosion. Macalloy 1030   Threads                      be used satisfactorily for short
                is, of course, subject to surface                                 tendons and bolts, as loss of load
                corrosion  when    exposed   to  A coarse thread is cold rolled  due to ‘take up’ in the threads on
                moisture and deep corrosion pitting   directly on to the bar. Bars can be  transfer of load, is minimised by
                is harmful. Further data is available   end threaded or fully threaded.  the controlled limits on clearance,
                from the Technical Department.                                    between internal and external
                                                 The bond value of the coarse  threads.


































                                                               ´