PA I R E D  C A B L E S                                                                            204

        Audio, Control and Instrumentation Cables




                      ®
        Overall Beldfoil Shield






                                                Insulation    Jacket         Capacitance
                        Color      OD (Nom)                                                    Additional Features/
          Part No.  Pairs                       Thickness   Thickness  Cond. - Cond.  Cond. - Shield
                        Code                                                                       Ratings
                                Inch    mm     Inch  mm    Inch  mm   pF/Ft  pF/m  pF/Ft  pF/m
        22 AWG • FEP/Flamarrest
         Stranded (19 x 34) TC Conductors • FEP Insulation • Overall Beldfoil Shielding • 22 AWG Stranded TC Drain Wire • White Flamarrest Jacket. Jacket and Shield Are Bonded So
         Both Can Be Removed on Automatic Stripping Equipment. Drain Wire Is Inside Foil Shield.
                                                                                                   Plenum
                       Black-Red,                                                              Zipcord Construction
          9451DP  2            .127 x .269  3.43 x 6.86  .007  .18  .017  .43  35  115  67  220
                      Black-White                                                             NEC: CMP • CEC: CMP FT6
                                                                                                   300V
        22 AWG • FEP/Flamarrest
         Stranded (7 x 30) TC Conductors • FEP Insulation • Overall Beldfoil Shielding • 22 AWG Stranded TC Drain Wire • Flamarrest Jacket (Black, Gray, Brown, Red, Orange, Yellow,
         Green, Blue, Purple, White)
          9451P   1    Black-Red  .127  3.23   .007  .18   .017  .43   35    115   67   220   NEC: CMP • CEC: CMP FT6

        22 AWG • FEP/Flamarrest  ®
         Stranded (7 x 30) TC Conductors • FEP Insulation • Overall Beldfoil Shielding • 22 AWG Stranded TC Drain Wire • Natural Flamarrest Jacket
          82761   1    Black-Red  .116  2.95   .006  .15   .014  .36   35    115   67   220   NEC: CMP • CEC: CMP FT6
        22 AWG • FEP/FEP
         Stranded (7 x 30) TC Conductors • FEP Insulation • Overall Beldfoil Shielding • 22 AWG Stranded TC Drain Wire • Red FEP Jacket
          88761   1    Black-Red  .119  3.02   .006  .15   .014  .36   35    115   67   220   NEC: CMP • CEC: CMP FT6
        22 AWG • FEP/Fluorocopolymer
         Stranded (7 x 30) TC Conductors • FEP Insulation • Overall Beldfoil Shielding • 22 AWG Stranded TC Drain Wire • Red Fluorocopolymer Jacket
          87761   1    Black-Red  .116  2.95   .006  .15   .014  .36   35    115   67   220   NEC: CMP • CEC: CMP FT6


































        TC = Tinned Copper• FEP = Fluorinated Ethylene Propylene

                            Fo r  m o r e  i n fo r m at i o n,  c o n t a c t   Be ld e n  Te ch n i ca l  S u ppo r t :   1- 8 0 0 - B E L D E N -1  •  www. b e l d e n . c o m