116 - AEI Cables Technical Data for Total Fire Solutions

Firetec Singlecore

No. of cores & Nominal    Current Rating (Enclosed in Conduit)                                      Voltage Drop                    Maximum DC Conductor                     Nominal Overall       Nominal Weight
   CSA of Conductor                                                                                                                     Resistance@ 20°C                          Diameter
                          Single Phase ac or dc         Three Phase ac              dc          Single Phase ac   Three Phase ac                                                                         Kg/Km
          no x mm²                                                                                                                                Ω/Km                               mm                   26.00
           1 x 1.50                  Amps                     Amps               mV/AM                mV/A/M           mV/A/M                    12.10                               3.50                 38.00
           1 x 2.50                  22.00                     19.00              31.00                31.00             27.00                    7.41                               4.10                 54.00
           1 x 4.00                  30.00                     26.00              19.00                19.00             16.00                    4.61                                4.6                 75.00
           1 x 6.00                  40.00                     35.00              12.00                12.00             10.00                    3.08                               5.10                124.00
          1 x 10.00                  51.00                     45.00               7.90                 7.90              6.80                    1.83                               6.70                183.00
          1 x 16.00                  71.00                     63.00               4.70                 4.70              4.00                    1.15                               7.60                285.00
          1 x 25.00                  95.00                     85.00               2.90                 2.90              2.50                    0.73                               9.40
                                     126.00                   111.00               1.90                 1.90              1.65

Firetec Standard

 No. of cores &                    Current Rating (Clipped Direct)               Voltage Drop                        Maximum DC     Nominal                         Nominal         Recommended Accessories
Nominal XSA of            Single Phase ac or dc Three Phase ac                                                         Conductor     Overall                        Weight
                                                                           dc     Single        Three Phase ac                      Diameter                                        Clips  Glands          Shrouds
   Conductor                                                                     Phase ac                         Resistance@ 20°C                                   Kg/Km
                                                                        mV/AM                                                          mm                             87.00         FCL30    FG1            FXG20
no x mm²                  Amps                          Amps             29.00   mV/A/M         mV/A/M                     Ω/Km        7.70                          129.00         FCL34    FG1            FXG20
 2 x 1.50                 19.50                            -             18.00                                             12.10       9.10                          110.00         FCL32    FG1            FXG20
 2 x 2.50                 27.00                            -                             29.00          -                   7.41       8.20                          163.00         FCL37    FG2            FXG20
 3 x 1.50                                                                   -                                              12.10       9.70                          139.00         FCL34    FG1            FXG20
 3 x 2.50                    -                          17.50               -            18.00          -                   7.41       9.20                          210.00         FCL43    FG2            FXG20
 4 x 1.50                    -                          24.00               -                                              12.10      10.90
 4 x 2.50                    -                          17.50               -              - 25.00                          7.41
                             -                          24.00
                                                                                           - 15.00
                                                                                           - 25.00

                                                                                           - 15.00

Firetec Enhanced

No. of cores &            Current Rating (Clipped Direct)                        Voltage Drop                     Maximum DC        Nominal    Nominal                       Recommended Accessories
                                                                                                                    Conductor        Overall   Weight
Nominal XSA of   Single Phase ac or dc Three Phase ac                  dc          Single      Three Phase ac                       Diameter
                                                                                 Phase ac                      Resistance@ 20°C                 Kg/Km
Conductor                                                           mV/AM                                                              mm       103.00                       Clips         Glands          Shrouds
                                                                     29.00                                              Ω/Km           9.10     140.00
no x mm²                  Amps                   Amps                18.00       mV/A/M         mV/A/M                  12.10          9.70     135.00                       FCL34         FG1             FXG20
 2 x 1.50                 19.50                     -                             29.00              -                   7.41          9.60     186.00                       FCL37         FG1             FXG20
 2 x 2.50                 27.00                     -                   -         18.00              -                  12.10         10.70     165.00                       FCL37         FG1             FXG20
 3 x 1.50                                                               -                                                7.41         10.70     234.00                       FCL43         FG2             FXG20
 3 x 2.50                    -                   17.50                  -        - 25.00                                12.10         11.90                                  FCL40         FG2             FXG20
 4 x 1.50                    -                   24.00                  -        - 15.00                                 7.41                                                FCL47         FG2             FXG20
 4 x 2.50                    -                   17.50                           - 25.00
                             -                   24.00                           - 15.00

Firetec Power

 No. of cores &                                  Current Rating                                  Voltage Drop        Maximum DC     Gross CSA of Armour                      Nominal Overall       Nominal Weight
Nominal XSA of                                      Single Way Ducts                            Three Phase ac         Conductor                                                  Diameter
                          Laid Direct                                            Free Air                                                                                                                Kg/Km
    Conductor                                                                                                     Resistance@ 20°C                                                   mm                  367.00
                                                                                                                                                                                    13.30                454.00
no x mm²                         Amps                      Amps                  Amps           mV/A/M            /Km                          mm²                                  14.70                556.00
                                                                                                                                                                                    16.00                783.00
4 x 1.50                         32.00                     26.00                 26.00          27.00             12.10                        17.00                                18.20

4 x 2.50                         42.00                     34.00                 35.00          16.00             7.41                         20.00

4 x 4.00                         55.00                     45.00                 47.00          10.00             4.61                         22.00

4 x 6.00                         69.00                     56.00                 107.00         6.80              3.08                         36.00

Current Ratings for 4x 10.0 to 4x 400.0 sqmm please refer to Firetec Impact Power. For further constructional information refer to our website www.aeicables.co.uk

Firetec Impact Power      Laid Direct            Current Rating                  Free Air        Voltage Drop        Maximum DC     Gross CSA of Armour                      Nominal Overall       Nominal Weight
                                                                                                                       Conductor                                                  Diameter
       No. of cores &        Amps                   Single Way Ducts              Amps          Three Phase ac                                  mm²                                                      Kg/Km
      Nominal XSA of                                                                                              Resistance@ 20°C                                                   mm
                              55.00                          Amps                 47.00              mV/A/M                                     42.00                                                    812.00
          Conductor           69.00                                               59.00                                    Ω/Km                 42.00                               20.00                853.00
                              92.00                          45.00                82.00                10.00                                    42.00                               20.00               1029.00
           no x mm²          119.00                          56.00                107.00                6.80                4.61                50.00                               20.00               1367.00
                             152.00                          75.00                140.00                4.00                3.08                70.00                               22.50               2240.00
            4 x 4.00         182.00                          96.00                172.00                2.50                1.83                78.00                               29.90               2705.00
            4 x 6.00         217.00                         124.00                209.00                1.65                1.15                90.00                               33.50               3375.00
           4 x 10.00         266.00                         149.00                363.00                1.15                0.73               131.00                               37.10               4560.00
           4 x 16.00         319.00                         177.00                324.00                0.87                0.52               147.00                               39.10               5805.00
           4 x 25.00         363.00                         218.00                376.00                0.60                0.39               206.00                               43.00               7430.00
           4 x 35.00         406.00                         263.00                430.00                0.45                0.27               230.00                               48.30               8820.00
           4 x 50.00         458.00                         300.00                495.00                0.37                0.19               255.00                               52.40               10600.00
           4 x 70.00         529.00                         338.00                584.00                0.30                0.15               289.00                               56.60               13380.00
           4 x 95.00         592.00                         382.00                666.00                0.26                0.12               319.00                               64.30               16255.00
           4 x 120.00        667.00                         442.00                766.00                0.21                0.10               452.00                               70.70               21145.00
           4 x 150.00                                       496.00                                      0.19                0.08                                                    80.30
           4 x 185.00                                       570.00                                      0.17                0.06
           4 x 240.00                                                                                                       0.05
           4 x 300.00
           4 x 400.00

Firetec FRF2                     Current Rating (Enclosed in Conduit)                               Voltage Drop                       Maximum DC                            Nominal Overall       Nominal Weight
                                                                                                                                         Conductor                                Diameter
  No. of cores & Nominal  Single Phase ac or dc            Three Phase ac           dc          Single Phase ac   Three Phase ac                                                                         Kg/Km
     XSA of Conductor                                                                                                               Resistance@ 20°C                                 mm                    135
                                 Amps                          Amps              mV/A/M              mV/A/M            mV/A/M                                                       10.00                  168
            no x mm²                                                              34.10                34.10                -                Ω/Km                                   11.20                  149
             3 x 1.50            23.00                             -              20.90                21.00                -                13.30                                  11.20                  211
             3 x 2.50            31.00                            -                   -                    -                                  7.98                                  12.40
             4 x 1.50                                          21.00                  -                    -             29.70               13.30
             4 x 2.50               -                          28.50                                                     17.60                7.98
                                    -

Mineral Insulated

           Conductors     Cables exposed to touch                      Sheath    Earth Fault     Maximum       Cable diameter    Cable weight                       Recommended accessories
                                                                      effective      loop       conductor             (mm)          (Kg/km)
Cable ref        Size     Current rating (amps)            Volt drop                            resistance                                     Glands & seals                              Copper fixings
                 (mm2)                                      MV/A/m       CSA     impedance      (ohm/km at      Bare LSZH        Bare LSZH
           No                                                          (mm2)       (R1+R2)
                                                                                  (ohms/m)          20°C)
                          Bare          LSF covered                                                                                            Gland ref RGM                 One hole clips Two-way saddles

2L1.5      2 1.5          21.0          23.0               28.0             6.3  21.2           12.1              5.7 7.0 131 154              20                   20 22 28 222 302

2L2.5      2 2.5          28.0          31.0               17.0             8.2  13.3           7.4               6.6 7.9 180 206              20                   20 26 32 272 342

3L1.5      3 1.5          17.0          19.0               24.0             7.8  20.6           12.1              6.4 7.7 168 194              20                   20 24 30 272 342

3L2.5      3 2.5          23.5          26.0               14.0             9.5  12.9           7.4               7.3 8.8 222 272              20                   20 28 34 302 342

4L1.5      4 1.5          17.0          19.0               24.0             9.1  20.2           12.1              7.0 8.3 203 231              20                   20 28 34 302 342

4L2.5      4 2.5          23.5          26.0               14.0         11.3     12.5           7.4               8.1 9.6 286 336              20                   20 32 37 342 422

2H1.5      2 1.5          22.5          25.0               28.0         11.0     19.8           12.1              7.9 9.4 224 259              20                   20 30 37 342 382

2H2.5      2 2.5          31.0          34.0               17.0         13.0     12.4           7.4               8.7 10.2 275 314             20                   20 34 40 342 422

       Extended ranges are available for all of the above cable types – refer to our website for additional information or contact sales@aeicables.co.uk

AEI Cables                                              Tel : +44 (0) 191 410 3111
Durham Road                                             Fax : +44 (0) 191 410 8312
Birtley
County Durham                                    Email : sales@aeicables.co.uk
DH3 2RA                                          Website : www.aeicables.co.uk
   115   116   117   118   119   120   121   122   123   124   125